Cornelius IAC522, IAC 322, IAC227, CR800, CR1200, CR1400, IWC530, IWC330 IAC 522 & IWC, IAC 530 & IWC

Models: IAC530 IWCS227 IWC522 IAC522 IAC330 IWC322 IWC330 IWC530 CR1400 CR1200 CR800 IAC227 IAC 322

1 83
Download 83 pages 13.44 Kb
Page 61
Image 61
IAC 522 & IWC 522

 

 

 

WH

 

 

 

 

 

 

GR

 

 

 

 

 

COMPRESSOR

COMPRESSOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RUN

START

 

 

 

COMPRESSOR

CAPACITOR

CAPACITOR

 

 

CONTACTOR

 

 

 

 

 

 

 

 

 

 

 

 

BK

 

 

BR

 

 

RD

 

RD

 

 

 

R

 

 

 

 

 

 

 

 

30 mfd

 

 

 

 

 

 

C

 

 

 

 

 

 

 

S

440 VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BK

 

BK

 

 

YL

 

72-86 mfd

 

 

 

 

 

 

 

330 VAC

 

 

 

 

 

 

EXTERNAL

 

 

 

 

 

 

 

YL

 

 

 

 

 

 

COMPRESSOR

 

 

 

 

 

 

 

 

 

 

WH

M

 

 

OVERLOAD

 

OR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT

 

 

BR

 

 

 

2

 

 

 

 

 

 

 

 

SWITCH

 

 

BK

 

 

POTENTIAL

5

 

 

 

 

 

 

 

 

 

BL

CONDENSATION

 

 

 

 

 

 

 

 

 

1

 

 

1

FAN (W/C ONLY)

 

 

START RELAY

 

 

 

 

 

 

 

 

 

 

 

 

2

3

 

 

 

 

 

 

WH

 

 

 

 

 

 

 

 

 

 

 

 

MANUAL RESET

 

 

 

 

 

 

 

 

 

HIGH PRESSURE

 

 

 

 

 

 

 

 

 

CONTROL(W/C ONLY)

 

 

 

WH

 

BR

 

 

 

 

 

 

 

WATER DUMP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VALVE

 

 

 

 

CO

 

 

 

 

 

 

 

 

450 PSIG

BL

BK

 

 

 

WH

 

BL

 

BR

 

 

1

WATER DUMP

 

 

 

 

 

 

3

2

SWITCH

 

 

 

 

 

 

 

 

 

 

 

CONDENSER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAN MOTOR

 

 

 

 

 

 

YL

 

 

 

 

(A/C ONLY)

 

 

 

 

 

 

 

 

 

 

M

BK

 

 

D-15

 

Water

 

 

BK

 

 

 

 

 

GR

Dump

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D-13

 

 

Valve

 

 

 

 

 

 

WH

 

D-14

 

 

 

 

 

 

RH Evap.

YL

 

GR

Relay

 

7

8

 

 

 

 

Switch

 

 

 

 

 

 

 

RH Evap.

 

 

 

5

6

 

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BL

 

 

S

 

 

GR

Water

 

3

4

WH

 

 

 

 

 

Pump

 

 

 

 

 

 

 

 

 

1

2

 

 

 

 

 

D-12

 

 

 

 

 

 

YL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D-10

 

 

D-11

 

 

 

 

 

 

 

(White Lead)

LH Evap.

 

Hot Gas

 

 

 

 

 

 

 

GR

 

 

 

 

WH

 

Condenser

 

 

 

Valve

230V

RD

 

 

WH

 

 

 

 

 

 

 

Sensor

Condenser

 

 

Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

See note 1

Plug

 

 

 

 

 

 

 

PUMP

 

 

 

 

 

Selector

 

 

 

 

 

 

 

 

 

 

 

 

 

CORD

 

 

Suction

 

 

D-6

Condenser

Switch

 

 

 

 

Suction Line

Plug

 

 

GR

 

 

 

 

 

 

 

 

 

Fan

115V

 

 

 

 

 

Sensor

 

 

 

 

 

 

 

HOT GAS

 

 

(Brown Lead)

Test

 

 

RD

 

 

 

 

 

 

 

Plug

 

 

D-5

 

 

 

 

SOLENOID

M

 

 

Options

 

Error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Plug

Adjustable Ice

Transformer

BL

 

 

 

 

 

 

 

 

 

 

 

 

Thickness Pot.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Micro

 

 

 

 

 

 

 

 

WATER PUMP

To Stacked

 

 

 

 

 

 

 

 

 

 

Processor

 

 

 

 

 

 

 

 

 

Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(if required)

Stacking

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cable

 

 

Manual

 

 

 

 

 

 

 

Plug

 

 

Harvest

 

 

 

 

IAC 522 & IWC 522

 

 

 

 

 

Switch

 

 

 

 

 

 

 

 

 

 

 

 

BL

 

 

IAC 530 & IWC 530

 

NOTE 1: CONDENSER SENSOR USED ONLY ON A/C UNITS. 1.8K ohm RESISTOR USED ONLY ON W/C UNITS.

12/1/94

58

166240004

Rev 3/4/96

 

 

Page 61
Image 61
Cornelius IAC522, IAC 322, IAC227, CR800, CR1200, CR1400, IWC530, IWC330, IWC322, IAC330, IWC522 IAC 522 & IWC, IAC 530 & IWC