Cornelius IWC522, IAC 322, IAC227, CR800, CR1200, CR1400, IWC530, IWC330, IWC322 SPECIFICATIONS - 50 HZ

Models: IAC530 IWCS227 IWC522 IAC522 IAC330 IWC322 IWC330 IWC530 CR1400 CR1200 CR800 IAC227 IAC 322

1 83
Download 83 pages 13.44 Kb
Page 10
Image 10
SPECIFICATIONS – 50 HZ

12/1/94 Rev 3/4/96

SPECIFICATIONS – 50 HZ

 

IAC322E50

IWC322E50

IAC522E50

IWC522E50

 

IAC522E50L

IWC522E50L

MODEL

IAC330E50

IWC330E50

IAC530E50

IWC530E50

 

IACS277E50

IWCS227E50

 

IAC530E50L

IWC530E50L

 

 

 

 

 

 

 

 

UNIT

Volts

Phase

Hertz

No. Wires

MIN. CIRCUIT

220

1

50

2+ground

220

1

50

2+ground

220

1

50

2+ground

220

1

50

2+ground

7

Amps

15

 

15

15

15

MAX FUSE SIZE (HVAC CIRCUIT BREAKER REQUIRED)

 

 

 

Amps

 

 

15

 

 

15

 

15

15

REFRIGERANT

 

 

 

 

 

 

 

 

 

 

Type

R404A(HP62)

 

R404A(HP62)

R404A(HP62)

R404A(HP 62)

Weight (oz)

17

 

15

26

23

Weight (g)

482

 

425

737

652

COMPRESSOR

 

 

 

 

 

Volts

220

220

Phase

1

1

Hertz

50

50

LRA

26

26

RLA

5.3

5.3

 

 

 

CONDENSER FAN MOTOR (Air-Cooled Systems only) or

AIR CIRCULATION FAN MOTOR (Water-Cooled and Remote Systems only)

220

1

50

33

8.2

220

1

50

33

8.2

Volts

Phase

Hertz

Amps Running Watts

WATER PUMP

220

1

50

0.75

50

220

1

50

0.3

6

220

1

50

0.75

50

220

1

50

0.3

6

166240004

Volts

Phase

Hertz

Amps Running

HP

220

1

50

0.5

1/30

220

1

50

0.5

1/30

220

1

50

0.5

1/30

220

1

50

0.5

1/30