Trouble

Probable Cause

Remedy

ICE WEIGHT LIGHT AT TOP

A. Float stuck open.

A. Replace the float valve.

OF PLATE AND HEAVY AT

 

 

THE BOTTOM

 

 

NOTE: REVIEW DRAWING ON PAGE 19 OF THIS MANUAL FOR NORMAL ICE SLAB.

B.Flow control washer missing from the float or installed upside-down (numbers must be facing up).

C.Water flow rate over the evaporator too fast.

D.Water leaking around curtain and pan; curtain frozen in the ice.

B.Replace or re-install as needed.

C.Check position of distribution tube (inner & outer).

D.Correct.

E.

Expansion valve flooding.

E.

Tighten and seal bulb. Replace

 

 

 

TXV if required.

F.

Condenser air re-circulating.

F.

Install baffle.

G.

Low charge.

G.

Leak check, evacuate & recharge.

H.Hot gas solenoid valve leaking. H. Replace.

I.

Evaporator wall gasket torn or I.

Replace.

 

missing, allowing condenser

 

 

air to reach top of evaporator.

 

 

 

 

SOFT WHITE ICE OR WATER A.

Distribution tube or water

PUMP NOT PUMPING

system scaled.

B. Water temperature too cold.

C.

Inadequate water system;

 

water pressure too low (below

 

20 PSI).

A.Clean distribution system as required.

B.50_F (10_C) minimum.

C.Correct.

D.

Inadequate water system; float

D.

Replace.

 

plugged or damaged.

 

 

E.

Distributor tubes – old style

E.

Replace with new style, 47 hole,

 

 

 

distributor tube. High flow tubes

 

 

 

require new style water curtains to

 

 

 

contain water.

 

 

 

 