RS-232C

 

Controlling Multiple Set

 

 

 

Transmission / Receiving Protocol

16. Abnormal state (Command: z)

Abnormal State: Used to Read the power off status when Stand-by mode. Transmission

[k][z][ ][Set ID][ ][Data][Cr]

Data FF: Read

Acknowledgement

[z][ ][Set ID][ ][OK][Data][x]

0:Normal (Power on and signal exist)

1:No signal (Power on)

2:Turn the monitor off by remote control

3:Turn the monitor off by sleep time function

4:Turn the monitor off by RS-232C function

8:Turn the monitor off by off time function

9:Turn the monitor off by auto off function

17. ISM mode(Command: j p)

Used to select the afterimage preventing function. Transmission

[j][p][ ][Set ID][ ][Data][Cr]

Data 1H: Inversion

2H: Orbiter

4H: White Wash

8H: Normal

Acknowledgement

[p][ ][Set ID][ ][OK][Data][x]