RS-232C

 

Controlling Multiple Set

 

 

 

Transmission / Receiving Protocol

23.Tile H Size(Command: d g) ► To set the Horizontal size.

Transmission

[d][g][ ][Set ID][ ][Data][x]

Data

Min: 00H to Max: 64H

*Refer to 'Real data mapping' page A7.

Acknowledgement

[g][ ][Set ID][ ][OK/NG][Data][x]

24.Tile V Size(Command: d h) ► To set the Vertical size.

Transmission

[d][h][ ][Set ID][ ][Data][x]

Data

Min: 00H to Max: 64H

*Refer to 'Real data mapping' page A7

Acknowledgement

[h][ ][Set ID][ ][OK/NG][Data][x]

A16

Page 70
Image 70
LG Electronics M4214CCBA owner manual A16