RS-232C

 

Controlling Multiple Set

 

 

 

Transmission / Receiving Protocol

30.Elapsed time return(Command: d l) ► To read the elapsed time.

Transmission

[d][l][ ][Set ID][ ][Data][x]

* The data is always FF(in Hex).

Acknowledgement

[l][ ][Set ID][ ][OK/NG][Data][x]

*The data means used hours. (Hexadecimal code)

31.Temperature value (Command: d n) ► To read the inside temperature value.

Transmission

[d][n][ ][Set ID][ ][Data][x]

* The data is always FF(in Hex).

Acknowledgement

[n][ ][Set ID][ ][OK/NG][Data][x]

* The data is 1 byte long in Hexadecimal.

32.Lamp fault Check(Command: d p) ► To check lamp fault.

Transmission

[d][p][ ][Set ID][ ][Data][x]

* The data is always FF(in Hex).

Acknowledgement

[p][ ][Set ID][ ][OK/NG][Data][x]

Data 0: Lamp Fault

1:Lamp OK

2:N/A(DPM/Power Off)

A19

Page 73
Image 73