On Screen Display(OSD) Selection and Adjustment
|
| Main menu | Sub menu | Description | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PRESET Mode
COLOR TEMP
PRESET
Select either PRESET or USER to adjust the screen color.
Select the screen color.
•WARM : Slightly reddish white.
•MEDIUM : Set the screen color to fit the sRGB standard color specification.
•COOL : Slightly bluish white.
USER Mode
USER | RED |
| Set your own red color levels. |
GREEN
Set your own green color levels.
BLUE
Set your own blue color levels.
GAMMA Set your own gamma value. : GAMMA 0 / GAMMA 1 / GAMMA 2 On the monitor, high gamma values display whitish images and low gamma values display blackish images.
DICOM GAMMA Use this function to set the DICOM GAMMA.
When you select DICOM GAMMA "ON" the monitor gamma values are set for the medical characteristic and luminance keeps factory default value.
: Move to the upper menu
: Decrease
: Increase
: Select another
NOTE
If you want to exit, select
and press "EXIT".
16