Troubleshooting

OAT100R Setup

The following sections provide basic troubleshooting information for the OAT100R.

Equipment Setup Review

Make sure all connectors and connections are tight and secure on all entertainment system components.

Check the OAT100R PWR LED. Under standard operating conditions, the PWR (Power) LED on the OAT100R front panel is continuously lit green. If there is a hardware fault, the PWR LED will turn and stay red.

Note: When power is first applied to the OAT100R, the PWR LED initially flashes red and then turns green.

Check the OAT100R STATUS LED. When the OAT100R is booted and operating normally, the STATUS LED is continuously lit green.

Network Setup

If the network is configured for DHCP but the OAT100R has not been assigned an IP address, i.e., the Ctrl IP field in the OAT100R System Information display is blank:

1.Check the Control Port connector on the rear panel of the OAT100R. Make sure the cable connection is tight and secure.

2.Observe the green LED on the Control Port. Once the OAT100R is connected to the network, the LED will be lit continuously.

3.Contact the network administrator to verify the network status and check that the DHCP server is working properly.