INSTALLATION GUIDELINES
Area Requirements
Verify the following:
•Floors can support refrigerator’s weight plus approximately 1200 pounds (544 kg) of food weight.
•Finished kitchen floor height has to be level. Appliance must be shimmed to the floor level if the floor heights are not equal to make sure air vents are not obstructed.
•Remove anything attached to rear or side walls that can obstruct refrigerator opening.
•Cutout dimensions are accurate.
•Electrical outlet is in correct location.
Do not install this unit next to any other refrigerator or freezer except another Liebherr model. Liebherr models are designed to allow
!WARNING
ELECTROCUTION HAZARD
Electrical Grounding Required. This appli- ance is equipped with a
•DO NOT remove the round grounding prong from the plug.
•DO NOT use a
•DO NOT use an extension cord to connect power to the unit.
Customer’s Responsibility
A 115 Volt, 60 Hz, 15 Amp (20 Amp for
Blocking For Safety
The
Electrical Requirement
If codes require a separate grounding circuit to be used, have a qualified electrician install the circuit.
!WARNING
Do not ground to a gas pipe. Check with a qualified electrician if you are not sure the appliance is properly grounded. Do not have a fuse in the neutral or grounding circuit.
!WARNING
ELECTRICAL SHOCK HAZARD
•Electrically ground refrigerator.
•Do not use an extension cord.
•Failure to follow these instructions could result in fire or electrical shock.
Unit Venting
DO NOT restrict the air flow. Air flow must be pro- vided for the unit to operate. The factory air vents provide 31 square inches (200 cm²) of air flow per unit. If you are replacing the factory air vents with an overlay, the air flow must be the same or greater than the factory air vents.
A delight in freshness
WFI1051 / EWTN 2956 | 3 |