Model 500ERV

®

CLEAN • FRESH • AIR

Model 500ERV

SPECIFICATIONS

LATENT RECOVERY (MOISTURE) TRANSFER CORES

Modular (4 section) 2- Enthalpic, 2 Aluminum arranged for high efficiency crossflow ventilation.

MOTORS - Two PSC, 5 speed double shafted, 120 VAC, 3.15 Amps each (6.3 total on high speed). HP - 1/10, 1625 RPM. Watts - total on High Speed - 610.

FILTERS - Washable air filters in exhaust and supply air streams. BLOWERS - Centrifugal type rated at 530 cfm (250 L/s) free air delivery. Each air stream has two centrifugal blowers driven by two PSC motors.

AIRFLOW L/s (CFM)

282(600)

235(500)

190(400)

143(300)

94(200)

42(100)

PERFORMANCE

AIRFLOWS (Each Air Stream)

SPEED 5

4

3

2

1

25

(.1)

50

(.2)

75

(.3)

100

(.4)

125

(.5)

EXTERNAL STATIC PRESSURE IN PASCALS (in. W.C.)

6.3HIGH

3.8MED

3.1LOW

TOTAL CURRENT DRAW (AMPS) @ 120 VAC

CONNECTION DUCT SIZES Four - 14" x 8" (356 mm x 200 mm). MOUNTING - Unit to be set on support brackets hung by threaded rod type apparatus (brackets and rods not included).

DEFROST - Damper defrost system.

CASE - 20 gauge prepainted galvanized steel (G60) for superior corrosion resistance. Insulated with foil faced insulation duct liner where required to prevent exterior condensation. Drain connection, One - 1/2" (12 mm) O.D.

CONTROLS - ControlAir 15

WEIGHT 178 lbs. (81 kg) SHIPPING WEIGHT 203 lbs. (92 kg)

TEMPERATURE EFFECTIVENESS

EFFECTIVENESS

100%

 

 

90%

 

80%

NOTE: Exhaust Relative Humidity (RH) at 40%

94

143

190

235

282

(200)

(300)

(400)

(500)

(600)

AIRFLOW IN L/s (CFM)

 

 

 

 

 

inches (mm)

 

 

EXHAUST AIR

ENTHALPIC CORE

ALUMINUM CORE

EXHAUST AIR

 

 

 

 

 

FROM BUILDING

 

 

MOUNTING POINTS

 

TO OUTSIDE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 7/8"

 

 

 

 

 

 

 

5 7/8"

 

(150 mm)

 

 

 

 

 

 

 

 

 

 

NOTE:

 

 

 

 

 

(150 mm)

 

 

 

 

 

 

18 3/4"

 

 

18 3/4"

1 3/8"

 

Service clearance

 

 

 

1/4"

 

 

 

 

 

 

 

 

 

 

 

DIMENSIONS 500ERV1

 

 

 

 

is 30 in. (760 mm)

 

 

 

(475 mm)

(32 mm)

 

(475 mm)

(35 mm)

 

 

 

 

 

 

14"

8"

 

14"

8"

 

 

 

 

 

 

(356 mm)

(200 mm)

 

 

 

 

 

(356 mm)

(200 mm)

 

 

 

 

 

 

 

 

 

SUPPLY AIR

 

49"

 

 

28 1/4 "

 

 

28 1/4"

 

FROM OUTSIDE

 

 

 

 

 

 

 

(1245 mm)

 

SUPPLY AIR

(717 mm)

 

 

(717 mm)

 

DEFROST DRAIN CONNECTION

 

 

TO BUILDING

INTERIOR DUCT

 

EXTERIOR DUCT

 

FRONT VIEW

 

 

 

 

 

 

 

 

 

 

 

CONNECTION SIDE

 

CONNECTION SIDE

OPTIONS

 

 

 

 

All units conform to CSA and UL standards.

 

99-104 Digital Electronic Timer - 20/40/60 min. (3 wire) 99-105 Programmable Ventilation Control includes

Programmable Time Clock, Dehumidistat and Air Sentry™

99-109 Air Sentry™ Air Quality Monitor designed to accept remotely mounted Control Pad

WARRANTY

Units carry a 5 year warranty on the energy recovery cores, a 15 year warranty on aluminum cores and a 2 year replacement parts warranty.

ERVs are not recommended for regions where the design temperature is below 25°F (-4°C)

DATE: __________________________

 

511 McCormick Blvd.

PROJECT: ________________________________________

London, Ontario N5W 4C8

Ph: (519) 457-1904

 

 

Fx: (519) 457-1676

MECHANICAL CONTRACTOR: ________________________________

Email: nutech@lifebreath.com

Website: www.lifebreath.com