Impinger I -–1000 Series Service Manual - Domestic34
THERMOSTAT, COOLING FAN
1. Shut off power at main breaker.
2. Remove control panel to p and front cover.
3. Remove lead wires and m ark for reassembly.
4. Remove two (2) scre ws and remove thermostat.
5. Reassemble in revers e order.
BURNER BLOWER MOTOR
1. Shut off power at main bre aker.
2. Remove control panel to p and front panel.
NOTE: Complete burner blower motor assembly, with control box (p/n 36935 9), is no longer
available. The burner blower assembly (p/n 369265) has been changed to a b urner motor kit
(p/n 369366). When It is used in the 3 ft Impinger Gas oven, the following m odification must be made:
3. Remove control box and components mounted on burner blower motor.
4. Mount transform er on air switch bracket as shown (use transformer as template).
5. Remove three (3) scr ews that attach blower assembly to burner housing.
6. Mount new blower ass embly.
7. Wire as shown. See pag e 35.
8. Discard control box an d relay.
9. Transfer air shutter assem bly from old blower assembly to new blower assembly.
MATERIAL NEEDED: #29 drill bit and #8 x 3/8 self tapping screws (3 each)
SEPARATE GROUND SCREW
AIR SWITCH MOUNTING BRACKET
MOUNTING HOLES
(USE #29 DRILL)
#8 X 3/8
SELF TAPPING
SCREW