TROUBLESHOOTING GUIDE
MODEL | NATURAL GAS | 230 VAC | 50 HZ | 1 PHASE |
MODEL | L.P. GAS | 230 VAC | 50 HZ | 1 PHASE |
NOTE: When checking components on left side of unit, be sure to check for proper connections in power connector, ( marked P. C. on schematic diagram ) located inside motor cover.
SYMPTOM | POSSIBLE CAUSE | EVALUATION |
Oven fan will | Incoming power supply | Check breakers/ reset if required |
not run |
| call Power company if needed |
| Oven fan switch | Check continuity between |
|
| switch terminals. |
| Thermostat, | Terminals are normally closed, if |
|
| open, reset thermostat and test |
|
| oven for proper operation. If it |
|
| will not reset, replace thermostat. |
| Fan fuse | Check, replace if necessary. |
| Fuse holder | Check, replace if necessary. |
| Oven fan relay | Check for power to coil of oven |
|
| fan relay. If no voltage is present, |
|
| trace wiring back to |
|
| Check for supply voltage at terminal |
|
| #6 of the relay. If no voltage is present, |
|
| trace wiring back to fuse holder. If |
|
| voltage is present, at the relay coil, check |
|
| to insure the contacts are closing. |
| Capacitor(s) | Check for opens, shorts, or grounds. |
| Motor (s) | Check for opens, shorts, or grounds. |
No control box cooling | Fan switch | (SEE OVEN |
| FAN WILL | |
| Oven fan relay | NOT RUN.) |
| Cooling fan(s) | Supply voltage should now be at these |
|
| motors. If voltage is present, check |
|
| motor for open, shorts, or grounds. |
|
| WITH POWER OFF: check for |
|
| locked rotor. |
No automatic control | Incoming power supply | Check circuit breakers, reset if needed. |
box cooling |
| Call power company if needed. |
| Cooling fan thermostats | Thermostat closes at 120°F and |
|
| opens at 100°F. With the cooling |
|
| fan thermostat preheated, check |
|
| for continuity. If switch is open, replace. |
| Cooling fan(s) | Supply voltage should now be at these |
|
| motors. If voltage is present, check |
|
| motor for opens, shorts or grounds. |
|
| WITH POWER OFF: Check for |
|
| locked rotor. |
Oven will not heat | Gas supply | Check for adequate gas supply to oven. |
| Manual gas shut off valve | Check to see that the manual gas shut |
|
| off valve is open. |
| Fan switch | Check to see that the fan switch is on. |
| Main oven fan | Check if main oven fan is operating. |
|
| if not, refer to “oven fan will not run”. |
NOTE: These ovens utilize 2 complete Burner/Temperature control systems. Each system will | ||
Follow the same troubleshooting sequence. |
| |
| Fuse, burner 3A. | Check, replace if necessary. |
6 | Low Profile – 1600 Advantage Series Service Manual – International |