TROUBLESHOOTING GUIDE
120/230VAC | 60 HZ. | 1 PHASE | |
120/230VAC | 60 HZ. | 3 PHASE | |
120/230VAC | 60 HZ. | 1 PHASE | |
120/230VAC | 60 HZ. | 3 PHASE | |
120/230VAC | 60 HZ. | 1 PHASE | |
120/230VAC | 60 HZ. | 3 PHASE |
*NOTE:
Model number ending in TS indicates top belt is split belt
Model number ending in SB indicates bottom belt is split belt
Model number ending in SS indicates both belts are split belts
SYMPTOM | POSSIBLE CAUSE | EVALUATION |
Oven fan will not run | Incoming power supply | Check circuit breakers. Reset if required. Call power |
|
| co. if needed. |
| Fuse, 2 Amp, control (F7) | Check, replace if necessary. |
| Fuse holder | Check, replace if necessary. |
| Switch, oven fan | Check continuity between switch terminals. Replace |
|
| switch as needed. |
| 30 minute time delay relay | Check for supply voltage to 30 minute time delay relay |
|
| at terminals #2 and #3. If no voltage is present, trace |
|
| wiring back to main power switch. If there is supply |
|
| voltage at terminals #2 and #3, check for output voltage |
|
| at terminals #1 and #3. If there is incoming voltage but |
|
| no output voltage, and the main power switch is on, |
|
| replace the 30 minute time delay relay. |
| Relay, main fan | Check for supply voltage to relay contacts, if no voltage |
|
| is present, trace wiring back to power supply. Check for |
|
| 120VAC to the coil of the main fan relay. If no voltage is |
|
| present, trace wiring back to the 30 minute time delay |
|
| relay, check to be sure that the Overload Protector |
|
| contacts are closed. If contacts are open, see |
|
| “Overload Protector” below. If voltage is present, check |
|
| to insure relay contacts are closing. Replace relay as |
|
| needed. |
| Overload protector, main fan | Check to be sure overload contacts are closed. If not |
|
| closed, |
|
| replace overload protector. If contacts close, test for |
|
| proper operation. If the overload contacts do not stay |
|
| closed, and the amperage is below the overload |
|
| setting, replace the overload protector. |
|
| 3240 should be set at 13A |
|
| 3260 should be set at 18A |
|
| 3270 should be set at 18A |
| Main fan motor | Check for supply voltage at motor. If no voltage is |
|
| present, trace wiring back to the overload protector. |
|
| WITH POWER OFF: Check for opens, shorts or |
|
| grounds. Turn motor shaft to check for locked rotor. |
| Capacitor | Check for shorts or grounds. |
|
| WARNING: Capacitor has a stored charge, discharge |
|
| before testing. |
| Drive belt | Check for loose or broken drive belt. Adjust motor for |
|
| proper belt tension (maximum of |
|
| replace drive belt as needed. |
|
|
|
| Bearings, Fan shaft | Check for any damage or excessive wear on the shaft |
6 | Impinger X2 – Analog Service Manual – Dom & Int’l |