| switch as needed. |
|
| Control, conveyor | Check for supply voltage to conveyor control at | |
|
| terminals #1 (AC) and #2 (AC). If no voltage is present, | |
|
| trace wiring back to conveyor switch. If AC voltage is | |
|
| present, check for DC voltage output at terminals #3 | |
|
| ||
|
| voltage out of the conveyor control. Replace the | |
|
| conveyor control. If there is D.C. voltage output, | |
|
| proceed. |
|
| Fuse, 2 Amp | Check, replace if necessary. | |
| Fuse holder | Check for D.C. voltage supplied to fuse holder. If no | |
|
| voltage is present, trace wiring back to conveyor | |
|
| control. Check fuse holder, replace if necessary. | |
| Switch, conveyor reversing | Check for D.C. voltage supplied to the reversing switch. | |
|
| If no voltage is present, trace wiring back to the fuse | |
|
| holder. Check continuity between switch terminals. | |
|
| Replace switch as needed. | |
| Conveyor motor | Check for D.C. voltage to the conveyor motor. If no | |
|
| voltage is present, trace wiring back to the reversing | |
|
| switch. If voltage is present and the motor will not run, | |
|
| check the motor windings for opens or shorts. Check | |
|
| motor brushes for excessive wear. Replace motor | |
|
| brushes as needed. | |
|
| If any of the above fails, replace conveyor motor. | |
| Conveyor | Check for any mechanical problems in the conveyor | |
|
| assembly. Check for damaged or torn belting. Check | |
|
| conveyor shaft bearings for damage or excessive wear. | |
|
| Repair or replace conveyor components as needed. | |
Conveyor speed varying or | Power supply | Check for a steady supply voltage to the conveyor | |
intermittent |
| control. If voltage is not steady, trace back to power | |
|
| supply. |
|
| Control, conveyor | Check for a steady DC voltage output at terminals A+ | |
|
| and | |
|
| 5 VDC output from the conveyor control at terminals | |
|
| +5V(red) and COM (black). If there is no voltage output, | |
|
| replace the conveyor control. If there is DC output, | |
|
| proceed. |
|
| Motor, conveyor | Check conveyor motor and gearbox for any visible | |
|
| damage. If there is apparent damage, repair or replace | |
|
| conveyor motor. Check motor brushes for excessive or | |
|
| abnormal wear. Replace motor brushes as needed. | |
| Hall effect sensor/magnet | Check to be sure that the Hall effect sensor and | |
|
| magnet are mounted on the motor. Check for any | |
|
| visible damage to the Hall effect sensor and magnet. If | |
|
| there is visible damage, repair or replace as needed. If | |
|
| there is no visible damage, check for a frequency | |
|
| output from the hall effect sensor at terminals SIG | |
|
| (white) and COM (black). | |
|
| Readings should be as follows: | |
|
| 2:15 cook time | 56 Hz. approx. |
|
| 5:00 | 25 Hz. approx. |
|
| 10:00 | 13 Hz. approx. |
|
| 16:00 | 8 Hz. approx. |
|
| If these readings are not achieved, replace the Hall | |
|
| effect sensor/magnet |
Impinger X2 – Analog Service Manual – Dom & Int’l | 15 |