Lincoln 3270-2 Repair or replace conveyor components as needed, Conveyor speed varying or, supply

Models: 3240-2 3270-2 3262-2

1 40
Download 40 pages 12.63 Kb
Page 10
Image 10

 

 

assembly. Check for damaged or torn belting. Check

 

 

conveyor shaft bearings for damage or excessive wear.

 

 

Repair or replace conveyor components as needed.

Conveyor speed varying or

Power supply

Check for a steady 120VAC supply to the conveyor

intermittent

 

control. If voltage is not steady, trace back to power

 

 

supply.

 

 

Control, conveyor

Check for a steady DC voltage output at terminals A+

 

 

and A-. If voltage is not steady, proceed. Check for

 

 

5 VDC output from the conveyor control at terminals

 

 

+5V(red) and COM (black). If there is no voltage output,

 

 

replace the conveyor control. If there is DC output,

 

 

proceed.

 

 

Motor, conveyor

Check conveyor motor and gearbox for any visible

 

 

damage. If there is apparent damage, repair or replace

 

 

conveyor motor. Check motor brushes for excessive or

 

 

abnormal wear. Replace motor brushes as needed.

 

Hall effect sensor/magnet

Check to be sure that the Hall effect sensor and

 

 

magnet are mounted on the motor. Check for any

 

 

visible damage to the Hall effect sensor and magnet. If

 

 

there is visible damage, repair or replace as needed. If

 

 

there is no visible damage, check for a frequency

 

 

output from the hall effect sensor at terminals SIG

 

 

(white) and COM (black).

 

 

Readings should be as follows:

 

 

2:15 cook time

56 Hz. approx.

 

 

5:00

25 Hz. approx.

 

 

10:00

13 Hz. approx.

 

 

16:00

8 Hz. approx.

 

 

If these readings are not achieved, replace the Hall

 

 

effect sensor/magnet

10

Impinger X2 – Analog Service Manual – Dom & Int’l

Page 10
Image 10
Lincoln 3270-2 Repair or replace conveyor components as needed, Conveyor speed varying or, intermittent, supply, proceed