Lincoln 3270-2 Remove control box cover, Display minimum setting value is in seconds, Jumper

Models: 3240-2 3270-2 3262-2

1 40
Download 40 pages 12.63 Kb
Page 25
Image 25
8.Remove control box cover.

CONVEYOR CONTROL – PROGRAMMING – DAYTON MOTOR, RIGHT ANGLE DRIVE

Jumper

“DART” Conveyor control with “UP”, “DOWN” and “ENTER” keys.

8.Remove control box cover.

9.Remove top cover from conveyor control. Locate program jumper on conveyor control and set jumper to the “ON” position.

10.Turn oven on, turn conveyor on. Press and hold the “ENTER” key until the Parameter Selection Mode is entered (display will indicate “P 0”).

11.Using the “UP” or “DOWN” keys, select the parameters to be changed (See chart below). When the parameter is selected, press “ENTER”. Use the “UP” or “DOWN” keys to set the desired parameter. Press “ENTER” to save the changes.

12.After all parameters are programmed, select parameter 0 and press the “ENTER” key to return to the running mode.

13.Set program jumper on conveyor control to “OFF”.

14.Reassemble in reverse order and check system operation.

Parameter

62” Oven

Explanation

10

2

Time Mode Setting (MM:SS)

20135 Display minimum setting (value is in seconds)

21960 Display maximum setting (value is in seconds)

30135 Display setting at reference RPM, parameter 31

311894 RPM at which display reference, should be displayed

321 Pulses per revolution of shaft encoder or pickup

50

7

Activate alarm when pickup stalled

53

1

Alarm flash enabled

98

5

Save parameter settings to user default area

Impinger X2 – Analog Service Manual – Dom & Int’l

25

Page 25
Image 25
Lincoln 3270-2, 3262-2 Remove control box cover, Display minimum setting value is in seconds, Jumper, Parameter, 62” Oven