| bearings. Replace bearings as needed. |
Oven will not heat | Gas supply | Check for adequate gas supply to oven. |
| Manual gas shut off valve | Check to see that the manual gas shut off valve is |
|
| open. Also, check flexible gas line connection for any |
|
| damage. |
| Main fan motor | Check for main fan operation. If it is not operating, refer |
|
| to “Oven fan will not run”. |
| Relay, main fan | Check for 120VAC supplied to relay terminal #13. If |
|
| voltage is not present, trace wiring back to power |
|
| supply. If voltage is present, check for 120VAC at |
|
| terminal #14. If there is no voltage at terminal #14, and |
|
| the relay is energized, replace the main fan relay. |
| Fuse, 2 Amp, control (F8) | Check, replace if necessary. |
| Fuse holder | Check, replace if necessary. |
| Switch, oven fan | Check for 120VAC to the switch, if no voltage is |
|
| present, trace wiring back to the main fan relay. Check |
|
| continuity between switch terminals. Replace switch as |
|
| needed. |
| Switch, burner | Check for 120VAC to the switch, if no voltage is |
|
| present, trace wiring back to the oven fan switch. |
|
| Check continuity between switch terminals. Replace |
|
| switch as needed. |
| Air pressure switch | Check for 120VAC to the air pressure switch. If no |
|
| voltage is present, trace wiring back to burner switch. |
|
| This normally open switch should close when the main |
|
| fan is activated. Check air switch tube for blockage or |
|
| any obstructions, repair as needed. Refer to the |
|
| “Removal and installation” section for proper |
|
| adjustment of air pressure switch. Replace air pressure |
|
| switch as needed. |
| Transformer, burner | Check for 120VAC supplied to primary of transformer. If |
|
| no voltage is present, trace wiring back to the air |
|
| pressure switch. If voltage is present, check for 24VAC |
|
| at transformer secondary. If there is primary voltage but |
|
| no secondary voltage, replace burner transformer. |
| Relay, burner blower | Check for 24VAC supply to relay coil. If no voltage is |
|
| present, trace wiring back to burner transformer. Check |
|
| for 120VAC to relay contact. If no voltage is present, |
|
| trace wiring back to air pressure switch. When 24VAC |
|
| is applied to the coil, there will be a delay of 20 – 30 |
|
| seconds. After this time delay, the relay contacts |
|
| should close. If there is 24VAC applied, but the |
|
| contacts do not close, replace the burner blower relay. |
| Motor, burner blower | Check for 120VAC supplied to the burner blower motor. |
|
| If no voltage is present, trace wiring back to the burner |
|
| blower relay. If voltage is present, and the motor is not |
|
| turning, check for opens, shorts or grounds. |
|
| WITH POWER OFF: Check for locked rotor. |
|
| Replace burner blower motor as needed. |
|
|
|
| Centrifugal switch of | Check for 24VAC supplied to centrifugal switch at wire |
| Burner blower motor | S5. If no voltage is present, trace wiring back to the |
|
| burner transformer. If voltage is present, check for |
|
| 24VAC out of centrifugal switch at wire #32. If there is |
|
| voltage in, but there is no voltage out, and the burner |
|
| blower motor is running, replace the burner blower |
|
| motor. |
|
|
|
| Burner control | Check for 24VAC supplied to the burner control at |
|
| terminals #5 and #6. If no voltage is present, trace |