OPERATION

b-6

 

 

 

AIR COMPRESSOR CONTROLS (24 THRU 26)

24. COMPRESSOR ON/OFF SWITCH

Turns compressor on and off (standby) by opening and closing the compressor inlet valve.

25. COMPRESSOR PROTECTION LIGHT

The yellow compressor protection light remains off with proper compressor oil temperatures. If the lights turn on, the compressor protection system will close the compressor inlet valve and put the system in standby mode until the temperature reaches allowable limits. Check for proper compressor oil level.

26. AIR DISCHARGE VALVE

Controls flow of compressed air. A 3/4” NPT (National Pipe Thread) fitting is provided.

FIGURE b.2

29

30

bATTERY JUMP START TERMINAL (27-28)

27.POSITIVE bATTERY JUMP START TERMINAL.

28.NEGATIVE bATTERY JUMP START TERMINAL.

12V battery jump start feature is standard. Covered output studs for convenient access, and protection against accidental impact. Can be used to jump-start a utility truck with up to 800 cold cranking amps. Can also be used to junp-start the AIR VANTAGE® 500 KUBOTA Cummins.

29. bATTERY DISCONNECT SWITCH

Battery disconnect switch provides lockout/tagout capability. Switch is conveniently located inside the engine compartment. (SEE FIGURE B.2)

30. AIR CLEANER SERVICE INDICATOR

Air cleaner service indicator provides a Go/No-Go visual indication of useful filter service life. Also locat-

ed inside the engine compartment. (SEE FIGURE B.2)

31. CIRCUIT bREAKERS

These circuit breakers provide separate overload cur- rent protection for each 120V circuit at the 240V single phase receptacle, each 120V single phase receptacle, the 240V three phase receptacle, the 120VAC in the 14-Pin connector, the 42VAC in the 14-Pin connector and battery circuit overload protection.

STARTING THE ENGINE

1.Remove all plugs connected to the AC power recepta- cles.

2. Set IDLER switch to AUTO.

3.Press Glow Plug Button and hold 15 to 20 seconds.

4.Set the RUN/STOP switch to RUN.

5.Press START button until the engine starts or for up to 10 seconds. Continue to hold the glow plug button for up to an additional 10 seconds.

6.Release the engine START button immediately when the engine starts.

7.The engine will run at high idle speed for approximately 12 seconds and then drop to low idle speed. Allow the engine to warm up at low idle for several minutes before applying a load and/or switching to high idle. Allow a longer warm up time in cold weather.

AIR VANTAGE® 500 KUbOTA