Lincoln Electric CV-300 manual LINCOLN POWER SOURCE TO AN LN-742

Models: CV-300

1 44
Download 44 pages 9.99 Kb
Page 34
Image 34
N.C. PINS NOT LISTED ARE NOT CONNECTED ON CABLE.

LINCOLN

 

POWER SOURCE

N.D.

 

 

14 PIN

 

AMPHENOL

 

LN-742

 

WIRE

WARNING

ELECTRIC

SHOCK

CAN KILL

LINCOLN POWER SOURCE TO AN LN-742 Turn off (0) the power switch on the Welding Power Source before connecting the wire feeder.

Only qualified persons should install, use or service this machine.

F-7

 

+ -

FEEDER

 

 

CV-300

TO WORK

LN-742

 

ELECTRODE CABLE

INPUT CABLE

 

ASSEMBLY

N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.

N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POLARITY, TURN POWER "OFF", REVERSE ELECTRODE AND WORK CABLES AT POWER SOURCE AND SET WIRE FEEDER VOLTMETER POLARITY SWITCH ON POWER SOURCE TO PROPER POLARITY.

N.C. PINS NOT LISTED ARE NOT CONNECTED ON CABLE.

N.D. IF USING K589-1, REMOTE CONTROL KIT,

SET POWER SOURCE CONTROL SWITCH TO "REMOTE" POSITION.

DIAGRAMS

FUNCTIONS ARE LISTED FOR REFERENCE ONLY AND EACH MAY OR MAY NOT BE PRESENT IN YOUR EQUIPMENT.

(SEE APPROPRIATE WIRING DIAGRAM)

PIN

LEAD

FUNCTION

 

 

 

C

2

TRIGGER CIRCUIT

D

4

TRIGGER CIRCUIT

E

77

OUTPUT CONTROL

F

76

OUTPUT CONTROL

G

75

OUTPUT CONTROL

H

21

WORK

I

41

42V AC

K

42

42V AC

 

K=42

 

I=41

 

H=21

C=2

 

D=4

G=75

 

E=77F=76

14-SOCKET BOX RECEPTACLE, FRONT VIEW AND 14-PIN CABLE PLUG, REAR VIEW

K=42

I=41

 

C=2

 

H=21

 

 

 

 

1-28-94

G=75

D=4

S20409

 

 

F=76

E=77

 

14-SOCKET BOX RECEPTACLE, REAR VIEW AND 14-PIN CABLE PLUG, FRONT VIEW

LINCOLN POWER SOURCE TO AN LN-742

F-7

Page 34
Image 34
Lincoln Electric CV-300 manual LINCOLN POWER SOURCE TO AN LN-742, N.C. Pins Not Listed Are Not Connected On Cable