OPTIONS TROUBLESHOOTING GUIDE

E-6

 

TROUBLESHOOTING

E-6

 

 

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

OPTIONS TROUBLESHOOTING GUIDE

 

 

K857 (or other) Remote Output Control

 

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

MISADJUSTMENTS

COURSE OF ACTION

 

 

 

 

 

 

PROBLEMS

Output control not functioning on

1.

Local/Remote switch in wrong

Remote Control.

 

position.

 

2.

Faulty Local/Remote switch.

 

3.

Faulty Remote Control poten-

 

 

tiometer.

 

4.

Leads or connections open in

 

 

control circuit.

 

5.

Faulty Control PC board.

 

 

 

 

Voltage Adjust not functioning on the

1.

Local/Remote switch in the

machine.

 

wrong position.

 

2.

Faulty Local/Remote switch.

 

3.

Faulty Voltage Adjust

 

 

potentiometer.

 

 

 

 

 

 

 

 

If all recommended possible areas of misadjustment have been checked and the problem persists,

Contact your local Lincoln Authorized Field Service Facility.

K857 (or other) Remote Output ControlCAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.