![Observe all Safety Guidelines detailed throughout this manual](/images/new-backgrounds/195449/19544943x1.webp)
TROUBLESHOOTING | ||
|
|
|
| Observe all Safety Guidelines detailed throughout this manual |
|
MACHINE TROUBLESHOOTING GUIDE
Not all trouble conditions can be recognized by the PC board, and displayed as error codes. The following guide covers most other trouble conditions.
| PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED |
|
| (SYMPTOMS) | MISADJUSTMENTS | COURSE OF ACTION |
|
|
|
|
|
|
|
| PROBLEMS |
|
|
|
|
|
|
|
Machine has no output. | 1. | Secondary contactor circuit (2 |
|
| and 4 wire feeder receptacle) not |
|
| working. |
| 2. | Electrode or work lead loose or |
|
| broken. |
| 3. | Defective PC Board. |
| 4. | Protective circuits operating due |
|
| to output short circuit. |
| 5. | If using an |
|
| plug kit not making connection |
|
| between 2 & 4 in wire feeder |
|
| receptacle. |
| 6. | If welding with 1/16" aluminum |
|
| wire and machine is flashing E00. |
Machine has minimum output and no 1. Voltage Control misconnected. control.
Machine has low output and no con- 1. Open in feedback circuitry. trol.
2. Faulty PC Board.
3. Voltage Adjust potentiometer circuit open (lead 75).
If all recommended possible areas of misadjustment have been checked and the problem persists,
Contact your local Lincoln Authorized Field Service Facility.