UpgradesandandTroubleshooting,co t’d

Upgrade and Troubleshooting Procedures

The following procedures may be done in the field.

Add Front Panel Controller (FPC-1000) - see Page 5-2.

Installing a Software Upgrade - see Page 5-4.

Swapping RS-232 / RS-422 Ports - see Page 5-5.

Troubleshooting a System Problem - see Page 5-6.

Adding Audio Cards to a Matrix 6400 Audio Switcher- see Page 5-8.

Changing the Audio Output Card Gain Jumpers - see Page 5-10.

Adding BMEs to a Matrix 3200/6400 System - see Page 5-11.

Adding a Front Panel Controller to an existing system

Adding a Front Panel Controller to an existing system involves replacing the blank Access Panel on any BME (except Sync) with the FPC-1000 panel. A system can only have one Front Panel Controller and it must be installed on BME #0. The details for installing the FPC-1000 are included in the User’s Manual provided with the unit.

RGB

 

 

 

 

MUTE

 

 

 

 

AUDIO

 

 

 

 

MUTE

 

 

 

 

 

 

 

 

FPC-1000

POWER SUPPLIES

 

 

SYSTEM

COMMUNICATIONS

+V

-V

 

 

STATUS

RS232

BME

REMOTE

 

PRIMARY

TX

 

 

 

REDUNDANT

RX

 

MATRIX 6400

 

 

DIAGNOSTICS

 

AUDIO

 

 

BME

 

 

-

 

 

4

 

 

+

A

ADDRESS

B

 

 

C

COMM.

 

D

 

E

 

 

A

MKP

 

B

 

C

 

 

D

 

 

E

ANAHEIM, CA

 

MADE IN USA

 

RS232/RS422

 

OUT

COMM.BME

 

IN

 

 

AC POWER INPUT

 

FUSE: 250V 5.0A TT

POWER CORD BEFORE SERVICING

 

0.5A MAX 50/60Hz

 

100-240V

DISCONNECT

 

 

 

INPUTS

 

 

 

 

 

 

OUTPUTS

 

 

 

IN

IN

IN

IN

IN

IN

IN

IN

OUT

OUT

OUT

OUT

OUT

OUT

OUT

OUT

1 - 8

9 - 16

17 - 24

25 - 32

33 - 40

41 - 48

49 - 56

57 - 64

1 - 8

9 - 16

17 - 24

25 - 32

33 - 40

41 - 48

49 - 56

57 - 64

Figure 5-1.A Matrix 6400 Audio BME Front and Rear Panels

5-2 Matrix 3200/6400 Series Upgrades and Troubleshooting

Page 44
Image 44
Extron electronic 3200s manual UpgradesandandTroubleshooting,co t’d, Upgrade and Troubleshooting Procedures