CV-305

DIAGRAM FOR WIRE FEEDERS THAT CLOSE A

SET OF CONTACTS TO GET POWER SOURCE OUTPUT:

LINCOLN POWER SOURCE 14-PIN WIRE FEEDER RECEPTACLE WITH K867 UNIVERSAL ADAPTER

 

 

N.A.

 

 

OUTPUT

115 V.A.C.

42 V.A.C.

N.B.

N.A.

CONTACTOR

 

CONTROL

SUPPLY

SUPPLY

 

}

}

}

}

 

4

2

31 32

41 42

GND 75 76 77

 

}

MIN.

MAX.

}

GND

 

 

 

 

 

WIRE FEEDER

 

 

10 K OHM

 

INPUT POWER

 

 

}

 

 

 

 

CONTACTS CLOSE

 

 

 

 

TO GET POWER

 

 

REMOTE OUTPUT

SOURCE OUTPUT

N.D.

 

 

CONTROL

NON-LINCOLN WIRE FEEDER

(IF SO EQUIPPED)

 

 

DIAGRAM FOR WIRE FEEDERS THAT SUPPLY A VOLTAGE TO GET POWER SOURCE OUTPUT:

LINCOLN POWER SOURCE 14-PIN WIRE FEEDER RECEPTACLE WITH K867 UNIVERSAL ADAPTER

N.A.

OUTPUT

115 V.A.C.

42 V.A.C.

N.B.

N.A.

CONTACTOR

 

CONTROL

SUPPLY

SUPPLY

 

}

}

}

}

 

4

2

31 32

41 42

GND 75 76 77

RELAY

RELAY CONTACT

 

(NORMALLY OPEN)

 

RELAY COIL

 

N.C.

}

}

MIN.

MAX.

GND

 

 

 

 

 

 

VOLTAGE SUPPLIED

WIRE FEEDER

 

 

10 K OHM

TO GET POWER

INPUT POWER

 

 

}

 

 

 

SOURCE OUTPUT

 

 

 

 

 

 

 

REMOTE OUTPUT

 

N.D.

 

 

CONTROL

NON-LINCOLN WIRE FEEDER

(IF SO EQUIPPED)

 

 

CONNECTION OF NON-LINCOLN WIRE

F-10

DIAGRAMS

N.A. CONNECTIONS 31 AND 32 MAY NOT BE PRESENT ON ALL MACHINES.

N.B. POWER SOURCE MUST BE PROPERLY GROUNDED.

N.C. RELAY COIL MUST BE RATED FOR THE SAME VOLTAGE THAT IS SUPPLIED BY THE WIRE FEEDER.

N.D. IF THE WIRE FEEDER REQUIRES AN INPUT VOLTAGE OTHER THAN 42 V.A.C., OR 115 V.A.C. ON SOME MACHINES, AN EXTERNAL POWER SUPPLY FOR THAT VOLTAGE MUST BE PROVIDED.

FEEDERS

F-10

Page 37
Image 37
Lincoln Electric CV-305 manual Connection of NON-LINCOLN Wire, Feeders