WARNING
ELECTRIC
SHOCK
CAN KILL
Turn off input power to the Welding Power Source using the disconnect switch at the fuse box Before connecting the wire feeder.
Only qualified persons should install, use or
service this machine.
N.C.
CV POWER
POWER SOURCE
14 PIN AMPHENOL
K867 UNIVERSAL
ADAPTER PLUG
+ | - |
| TO WORK |
| ELECTRODE CABLE |
81 | NOT USED ON | ||
82 | |||
SPARE |
|
| |
2 | CONNECT TOGETHER FOR | ||
4 | WELDING OUTPUT | N.D. | |
41 | 42 VAC |
| |
42 | N.E. | ||
| |||
31 |
| ||
115 VAC | N.F. | ||
32 | |||
POWER SOURCE FRAME CONNECTION | |||
GND | |||
21 | WIRE FEEDER VOLTMETER CONNECTION | ||
| CONNECTS TO (WORK TERMINAL) OF POWER SOURCE |
77 | 10K |
|
76 |
| REMOTE OUTPUT CONTROL |
75 | MIN. | N.F. |
SOURCE TO A K867 UNIVERSAL
DIAGRAMS
N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION. N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POLARITY, TURN POWER "OFF",
REVERSE ELECTRODE AND WORK CABLES AT POWER SOURCE. N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.
N.D. FOR WIRE FEEDERS THAT RETURN A SIGNAL FOR WELDING OUTPUT, USE ISOLATION RELAY TO CLOSE LEADS 2 & 4.
N.E. REFER TO POWER SOURCE INSTRUCTION MANUAL FOR MAXIMUM AUXILIARY CURRENT DRAW.
N.F. NOT PRESENT ON ALL MACHINES
{
TO 2
K867
4
TO WIRE FEEDER
S20658