Lincoln Electric CV-305 manual Controls and Output Settings, Thermal Protection Indication Light

Models: CV-305

1 41
Download 41 pages 59.93 Kb
Page 15
Image 15

B-4

OPERATION

B-4

 

 

 

CONTROLS AND OUTPUT SETTINGS

All operator controls and adjustments are located on the case front of the CV-305. Refer to Figures B.1.

FIGURE B.1 - CONTROL AND OUTPUT PANEL

5

4

8

7

6

10

11

1. POWER SWITCH

Atwo-position toggle switch.Controls the input power to the CV-305.

2.VOLTAGE ADJUST

Controls the CV-305 output voltage.

3. THERMAL PROTECTION INDICATION LIGHT

Indicates that the protection thermostat has activated. The digital meter will display "E10" when this occurs. When the light turns off, the machine will be capable of supplying welding out- put power again.

NOTE: Leaving the power switch in the "ON" posi- tion will result in the most rapid cooling.

4. VOLTS/AMPS SWITCH

Selects either output current or arc voltage to be displayed on the digital meter.

5. DIGITAL VOLTMETER/AMMETER

Displays the CV-305 output current, or the arc voltage.

3

1

2

9

13

12

NOTE: Due to voltage drops in the welding cables and at cable connection points, the actual arc voltage may be lower than that displayed on the voltmeter. Use welding cables of the proper capacity and make sure all connec- tions are tight to minimize this effect.

6. 42 VOLT CIRCUIT BREAKER

Protects the 42 volt 41-42 circuit in the wire feeder receptacle from overloads and shorts. If this circuit breaker opens, the CV-305 will work normally. However, any equipment powered by the 42 volt circuit will not work.

7. 115 VOLT CIRCUIT BREAKER

Protects the 115 volt 31-32 circuit in the wire feed- er receptacle from overloads and shorts. If this cir- cuit breaker opens, the CV-305 will work normally. However, any equipment powered by the 115 volt circuit will not work.

8. LOCAL/REMOTE SWITCH

Determines whether the welding voltage is con- trolled at the CV-305, or controlled remotely by a remote output control (such as a K857).

CV-305

Page 15
Image 15
Lincoln Electric CV-305 manual Controls and Output Settings, Thermal Protection Indication Light