Lincoln Electric CV-305 Machine Troubleshooting Guide, Problems Possible Recommended Symptoms

Models: CV-305

1 41
Download 41 pages 59.93 Kb
Page 22
Image 22

E-3

TROUBLESHOOTING

E-3

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

MACHINE TROUBLESHOOTING GUIDE

Not all trouble conditions can be recognized by the PC board, and displayed as error codes. The following guide covers most other trouble conditions.

PROBLEMS

POSSIBLE

RECOMMENDED

(SYMPTOMS)

CAUSE

COURSE OF ACTION

 

 

 

 

PROBLEMS

 

 

 

 

Machine has no output.

1. Secondary contactor circuit (2

 

 

and 4 wire feeder receptacle) not

 

 

working.

 

2.Electrode or work lead loose or broken.

3.Defective PC Board.

4.Protective circuits operating due to output short circuit.

5.If using an LN-25, K484 jumper plug kit not making connection between 2 & 4 in wire feeder receptacle.

6.If welding with 1/16" aluminum

wire and machine is flashing E00. If all recommended possible areas

of misadjustment have been checked and the problem persists,

Contact your local Lincoln

Authorized Field Service Facility.

Machine has minimum output and no 1. Voltage Control misconnected. control.

Machine has low output and no con- 1. Open in feedback circuitry. trol.

2.Faulty PC Board.

3.Voltage Adjust potentiometer circuit open (lead 75).

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CV-305

Page 22
Image 22