A-5

INSTALLATION

A-5

 

 

 

LOCATION / VENTILATION

The welder should be located to provide an unrestrict- ed flow of clean, cool air to the cooling air inlets and to avoid heated air coming out of the welder recirculating back to the cooling air inlet. Also, locate the welder so that engine exhaust fumes are properly vented to an outside area.

STACKING

RANGER® 3 PHASE machines cannot be stacked.

CONNECTION OF LINCOLN ELECTRIC WIRE FEEDERS

WARNING

Shut off welder before making any electrical connections.

------------------------------------------------------------------------

WIRE FEED (CONSTANT VOLTAGE) CONNECTION OF LN-15 ACROSS-ThE-ARC WIRE FEEDER

The LN-15 has an internal contactor and the electrode is not energized until the gun trigger is closed. When the gun trigger is closed the wire will begin to feed and the welding process is started.

Shut the welder off.

Connect the electrode cable from the LN-15 to the “ELECTRODE” terminal of the welder. Connect the work cable to the “TO WORK” terminal of the welder.

Connect Electrode leads appropriately to acquire desired polarity, either DC (-) or DC (+).

Attach the single lead from the front of the LN-15 to work using the spring clip at the end of the lead. This is a control lead to supply current to the wire feeder motor; it does not carry welding current.

Set the “RANGE” switch to the “WIRE FEED-CV” position

Place the Engine switch in the “Auto Idle” position when welding with MIG wire instead of self-shielded core wire, weld starts can be improved by setting the idle mode to “HIGH”.

Adjust the wire feed speed at the LN-15 and adjust the welding voltage with the output “CONTROL” at the welder. Output “CONTROL” must be set above 3 when welding with MIG wire instead of self-shielded core wire, weld starts can be improved by setting the idle mode to “HIGH”.

NOTE: LN-15 Control Cable model will not work with the RANGER® 3 PHASE.

Position the “RANGE” switch to the “WIRE FEED CV” position.

Attach the single lead from the LN-25 control box to the work using the spring clip on the end of the lead - it carries no welding current.

Place the engine switch in the “AUTO IDLE” posi- tion.

When welding with MIG wire instead of self- shielded core wire, weld starts can be improved by setting the idle mode to “HIGH”.

Adjust wire feed speed at the LN-25 and adjust the welding voltage with the output “CONTROL” at the welder.

NOTE: The welding electrode is energized at all times, unless an LN-25 with built-in contactor is used. If the output “CONTROL” is set below “3”, the LN-25 contactor may not pull in.

CONNECTION OF ThE LN-25 TO ThE RANGER® 3 PhASE

Shut the welder off.

Connect the electrode cable from the LN-25 to the“ELECTRODE” terminal of the welder. Connect the work cable to the “TO WORK” termi- nal of the welder.

Attach working and electrode leads appropriately to acquire desired polarity, either DC (-) or DC (+).

CONNECTION OF K930-2 TIG MODULE TO ThE RANGER® 3 PhASE.

The TIG Module is an accessory that provides high frequency and shielding gas control for DC GTAW (TIG) welding. See IM528 supplied with the TIG Module for installation instructions.

NOTE: The TIG Module does not require the use of a high frequency bypass capacitor. However, if the RANGER® 3 PHASE is used with any other high fre- quency equipment, the bypass capacitor must be installed, order kit T12246.

INSTRUCTIONS

ADDITIONAL SAFETY PRECAUTIONS

Always operate the welder with the roof and case sides in place as this provides maximum protection from moving parts and assures proper cooling air flow.

Read and understand all Safety Precautions before operating this machine. Always follow these and any other safety procedures included in this manual and in the Engine Owner’s Manual.

RANGER® 3 PhASE

Page 12
Image 12
Lincoln Electric IM10030 manual Instructions, Location / Ventilation, Stacking, Connection of Lincoln Electric Wire Feeders