OPERATION | ||
|
|
|
“ | RANGE” SWITCh |
|
The “Range” switch is used to select one of four amperage ranges with generous overlap for Stick/TIG welding, or one Wire Feed welding range.
| Process | Range Setting |
| Current Range | |
|
|
|
|
| |
|
|
|
|
|
|
| STICK/TIG | 90 Max. |
| 40 to 90 Amps | |
(constant current) | 145 Max. |
| 70 to 145 Amps | ||
(3 range settings) | 225 MAX |
| 120 to 225 Amps | ||
|
|
|
|
|
|
| WIRE FEED |
|
|
|
|
(constant voltage) | 15 to 25V |
| Up to 200 Amps | ||
(1 range setting) |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| CAUTION |
|
| |
|
|
|
|
|
|
Never change the “RANGE” Switch setting while welding. This will damage the switch.
“CONTROL” DIAL
Provides a fine welding current adjustment within the Range Switch settings in the STICK mode and weld- ing voltage control with the Range switch set in the wire feed mode.
RANGER® 3 PhASE APPROXIMATE FUEL CONSUMPTION
| KOhLER |
| 23 h.P. COMMAND Ch23S |
|
|
Low Idle - No Load | .40 Gallons/Hour |
2400 RPM | (1.50 Liters/Hour) |
High Idle - No Load | .7 Gallons/Hour |
3700 RPM | (2.8 Liters/Hour) |
DC CC Weld Output | 1.3 Gallons/Hour |
210 Amps @ 25 Volts | (4.9 Liters/Hour) |
DC CV Weld Output | 1.2 Gallons/Hour |
200 Amps @ 20 Volts | (4.5 Liters/Hour) |
|
|
Auxiliary Power Single Phase | 1.52 Gallons/Hour) |
9500 Watts | (5.77 Liters/Hour) |
Auxiliary Power 3 Phase | 1.64 Gallons/Hour) |
10,500 Watts | (6.23 Liters/Hour) |
|
|