Lincoln Electric IM10030 manual Ranger 3 PhASE Approximate Fuel Consumption, Control Dial

Models: IM10030

1 36
Download 36 pages 56.32 Kb
Page 18
Image 18

b-2

OPERATION

b-2

 

 

 

RANGE” SWITCh

 

The “Range” switch is used to select one of four amperage ranges with generous overlap for Stick/TIG welding, or one Wire Feed welding range.

 

Process

Range Setting

 

Current Range

 

 

 

 

 

 

 

 

 

 

 

 

STICK/TIG

90 Max.

 

40 to 90 Amps

(constant current)

145 Max.

 

70 to 145 Amps

(3 range settings)

225 MAX

 

120 to 225 Amps

 

 

 

 

 

 

 

WIRE FEED

 

 

 

 

(constant voltage)

15 to 25V

 

Up to 200 Amps

(1 range setting)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

 

 

 

 

 

Never change the “RANGE” Switch setting while welding. This will damage the switch.

------------------------------------------------------------------------

CONTROL” DIAL

Provides a fine welding current adjustment within the Range Switch settings in the STICK mode and weld- ing voltage control with the Range switch set in the wire feed mode.

RANGER® 3 PhASE APPROXIMATE FUEL CONSUMPTION

 

KOhLER

 

23 h.P. COMMAND Ch23S

 

 

Low Idle - No Load

.40 Gallons/Hour

2400 RPM

(1.50 Liters/Hour)

High Idle - No Load

.7 Gallons/Hour

3700 RPM

(2.8 Liters/Hour)

DC CC Weld Output

1.3 Gallons/Hour

210 Amps @ 25 Volts

(4.9 Liters/Hour)

DC CV Weld Output

1.2 Gallons/Hour

200 Amps @ 20 Volts

(4.5 Liters/Hour)

 

 

Auxiliary Power Single Phase

1.52 Gallons/Hour)

9500 Watts

(5.77 Liters/Hour)

Auxiliary Power 3 Phase

1.64 Gallons/Hour)

10,500 Watts

(6.23 Liters/Hour)

 

 

RANGER® 3 PhASE

Page 18
Image 18
Lincoln Electric IM10030 manual Ranger 3 PhASE Approximate Fuel Consumption, Control Dial