Lincoln Electric IM10041 Installation, Technical Specifications AIR Vantage 500 Cummins K32012

Models: IM10041

1 54
Download 54 pages 63 b
Page 11
Image 11

 

A-1

 

 

 

 

INSTALLATION

 

 

A-1

 

TECHNICAL SPECIFICATIONS - AIR VANTAGE® 500 CUMMINS (K32012)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT - DIESEL ENGINE

 

 

 

 

 

 

 

 

 

 

 

 

 

Make/Model

 

Description

 

Speed (RPM)

Displacement

Starting

Capacities

 

 

 

 

 

 

 

 

 

cu. in. (ltrs.)

System

 

 

 

 

4 cylinder

 

High Idle 1900

199(3.3)

 

12VDC Battery &

Fuel: 25 gal.

 

Cummins

 

56 HP (42kw)

 

 

 

 

 

starter

(94.6 L)

 

 

 

 

 

 

 

 

B3.3

 

1800 RPM

 

Full Load 1800

Bore x Stroke inch (mm)

 

 

Oil: 2 gal. (7.5L)

 

 

 

Diesel Engine

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low Idle 1425

3.74 X 4.53

 

 

Radiator Coolant:

 

 

 

 

 

 

 

 

 

(95 x 115mm)

 

 

2.6gal. (9.8L)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED OUTPUT @ 104°F(40°C) - WELDER

 

 

Duty Cycle

 

 

 

Welding Output

 

 

Volts at Rated Amps

 

100%

 

 

 

 

500 Amps (DC multi-purpose)

 

 

40 Volts

 

 

60%

 

 

 

 

550 Amps (DC multi-purpose)

 

 

36 volts

 

 

50%

 

 

 

 

575 Amps (DC multi-purpose)

 

 

35 volts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT @ 104°F(40°C) - WELDER AND GENERATOR

 

 

 

 

 

 

 

 

Welding Range

 

 

 

 

 

 

 

 

 

 

30 - 575 Amps CC/CV

 

 

 

 

 

 

 

 

 

 

20 - 250 Amps TIG

 

 

 

 

 

 

 

 

 

 

Open Circuit Voltage

 

 

 

 

 

 

 

 

 

 

60 Max OCV @ 1900 RPM

 

 

 

 

 

 

 

 

 

 

Auxiliary Power (1)

 

 

 

 

 

 

 

 

 

 

2 x 240 VAC Receptacles

 

 

 

 

 

 

 

 

 

 

2 x 3600 Watts 60Hz Single Phase

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

 

 

 

Height (2)

 

 

 

Width

 

Depth

 

Weight

 

42.0 in

 

 

 

32.7 in.

 

63.1 in.

 

1690 lbs.

 

(1066.8 mm)

 

 

(830.1mm)

 

(1603mm)

 

(766kg)

 

 

 

 

 

 

 

 

 

 

 

 

(Approx)

1.Output rating in watts is equivalent to volt-amperes at unity power factor.

Output voltage is within +/- 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.

2.Top of Enclosure, add 7.0” (177.8mm) for exhaust pipe.

AIR VANTAGE® 500 CUMMINS

Page 11
Image 11
Lincoln Electric IM10041 manual Installation, Technical Specifications AIR Vantage 500 Cummins K32012, Open Circuit Voltage