AIR VANTAGE® 500 CUMMINS

ENGINE WELDERS / K867 / K775 / LN-7 CONNECTION DIAGRAM

 

 

WARNING

 

 

 

 

 

Do not operate with panels open.

 

Keep guards in place.

 

 

Disconnect NEGATIVE (-) BATTERY LEAD

 

Keep away from moving parts.

 

 

before servicing.

 

Only qualified personnel should install,use

 

 

Do not touch electrically live parts.

 

or service this equipment.

 

 

 

SPARE

}

 

 

 

 

 

82

 

 

 

 

 

81

N.D.

LN-7

 

 

42

 

 

WIRE

 

 

 

 

FEEDER

 

 

41

 

 

 

 

 

 

31

 

 

31

 

 

 

32

 

 

32

 

 

14 PIN

2

 

 

2

 

 

AMPHENOL

4

 

 

4

 

 

 

 

 

 

ELECTRODE

TO WORK

21

 

 

21

K291 OR K404

 

K867 UNIVERSAL

GND

 

 

 

 

 

 

GND

INPUT CABLE

 

ADAPTER PLUG

 

 

 

 

 

 

GREEN

 

 

 

 

 

 

 

 

TO WORK

75

 

 

75

 

 

ELECTRODE CABLE

76

 

 

76

 

 

77

 

 

77

 

 

TO WIRE FEED UNIT

}

K775 OPTIONAL

CAUTION :

 

 

 

 

N.E.

 

 

REMOTE CONTROL

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE

AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE

DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN

THE ENGINE WELDER OPERATING MANUAL.

N.A. WELDING CABLE MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE

APPILICATIONS. SEE OPERATING MANUAL.

N.B. USE VOLTMETER SWITCH TO SELECT DESIRED ELECTRODE POLARITY. POSITION THE "SELECTOR" SWITCH TO "WIRE WELDING CV".

PLACE WIRE FEEDER SWITCH TO "WIRE FEEDER WITH CONTROL CABLE POSITION.

N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED,CONTROL IS AUTOMATICALLY SWITCHED TO REMOTE CONTROL.

N.D. INSULATE EACH UNUSED LEAD INDIVIDUALLY.

N.E. SPLICE LEADS AND INSULATE.

7-2000

S23983

F-3

DIAGRAMS

F-3

Page 40