Lincoln Electric IM524-D manual Output Connections, Work and Electrode Cable Connections

Models: IM524-D

1 54
Download 54 pages 51.66 Kb
Page 12
Image 12

A-4

A-4

INSTALLATION

FIGURE A.3 – FRONTPANEL/BACK PANEL

6

5

 

 

 

 

(IN)

 

 

 

 

(OUT)

 

 

 

 

4

 

1

3

2

 

1

WORK TERMINAL

 

4

WATER COOLING FITTINGS (ON ACCESS PANEL)

2

ELECTRODE TERMINAL

5

WIRE FEEDER CONNECTIONS (ON BACK PANEL)

3

REMOTE CONTROL AMPHENOL RECEPTACLE

6

ELECTRODE TERMINAL

To reconnect your machine for the proper input volt- age, see the reconnect instructions on your input access door and:

1.Move the large input voltage switch to the proper position according to your input volt- age, and the labels near the switch.

2.Move the auxiliary “A” lead to the appropriate terminal, according to your input voltage and the labels near the terminals.

OUTPUT CONNECTIONS

See Figure A.3 for the location of the work terminal, electrode terminal, remote control amphenol recepta- cle, water cooler fittings and wire feeder connections.

WORK AND ELECTRODE CABLE CONNECTIONS

Size

Use the largest welding (electrode and ground) cables possible — at least 70mm2 (#2/0) copper wire — even if the output current does not require it. When pulsing, the pulse current often exceeds 650 amps with the Power Wave 450. Voltage drops can become exces- sive if undersized welding cables are used.

Routing

To avoid interference problems with other equipment and to achieve the best possible operation, route all cables directly. Avoid excessive lengths, bundle the electrode and ground cables together where practical, and do not coil excess cable.

WATER COOLER CONNECTIONS

The water cooler fittings are a quick-connect type. Refer to the Accessories and Maintenance sections of this manual for water cooler operation and recom- mended coolants.

WIRE FEEDER CONNECTIONS

Refer to the Accessories section for Wire Feeder Con- nections.

Refer to Setup overlay in Operation section for Wire Feeder Configuration.

POWER WAVE 450

Page 12
Image 12