B-20

B-20

OPERATION

In Pulse processes:

The wave control adjustment allows the frequency setting to vary. Increasing the wave control allows the frequency setting to increase, and decreasing the wave control allows the frequency setting to decrease. Varying the wave control setting affects the droplet trans-fer and allows fine-tuning for different welding positions.

In Stick processes:

The wave control adjusts the arc force. Increasing the wave control setting increases the arc force, making the arc more harsh but less likely to stick. Decreasing the wave control setting decreases the arc force, making the arc softer and smoother.

In GMAW and FCAW processes:

The wave control adjusts the inductance. (Inductance is inversely proportional to pinch.) Increasing the wave control setting decreases the inductance, which results in the arc getting colder and pinched tighter. Decreasing the wave control setting increases the induc-tance, which results in the arc getting wider.

TABLE B.3 – ADJUSTBLE PARAMETERS

Adjustable

GMAW

GMAW

 

Parameters

Pulse

FCAW

Stick

Wire Feeder

Wire Feed

Wire Feed

WFS Display

Speed

Speed

 

Wire Feeder

Arc Length

Preset

Voltage Display

Trim

Voltage

 

Power Wave 450 Display

 

 

 

(with GMAW Pulse,

Wave

Wave

Wave

GMAW FCAW, Stick

Control

Control

Control

Process Selection Overlay)

(Frequency)

(Inductance)

(Arc Force)

 

 

 

 

TABLE B.4 – DISPLAYS OF THE POWER WAVE AND WIRE FEEDERS

FOR DIFFERENT PROCESSES IN BOTH TRIGGER POSITIONS

Trigger

 

Power Wave 450

 

Wire Feeder

 

 

 

 

 

 

 

 

 

 

 

 

Position1

GMAW

GMAW

 

STICK1

Pulse

GMAW

 

Pulse

FCAW

 

 

 

FCAW

 

 

 

 

 

WFS DISPLAY:

WFS DISPLAY:

 

 

 

 

 

Wire Feed Speed

Wire Feed Speed

 

WFS and

WFS and

 

Preset

VOLTAGE

VOLTAGE

Open

Arc Length Trim

Preset Voltage

 

Current

DISPLAY:

DISPLAY:

 

 

 

 

 

Arc Length Trim

Preset Voltage

 

WFS,

WFS,

 

 

WFS DISPLAY:

WFS DISPLAY:

 

Actual Arc

Actual Arc

 

Preset Current,

Wire Feed Speed

Wire Feed Speed2

Closed

Voltage,

Voltage,

 

Actual Arc

VOLTAGE

VOLTAGE

 

Actual Arc

Actual Arc

 

Voltage, Actual

DISPLAY:

DISPLAY:

 

Current

Current

 

Arc Current

Actual Arc Voltage

Actual Arc Voltage

 

 

 

 

 

 

 

1In Stick, trigger is on Remote Control Kit K941-1.

2Arc Current, not wire feed speed, is displayed if a Remote Control Kit is attached to the wire feeder.