1 54
Download 54 pages 51.66 Kb
Page 9
Image 9

A-1

 

 

INSTALLATION

 

 

 

 

 

 

A-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS - POWER WAVE 450

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT - THREE PHASE 50/60

HZ. ONLY

 

 

 

 

 

 

 

 

 

Input Voltages:

200

 

230

 

 

 

400

 

 

460

 

575

 

 

 

 

Input Currents

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

@ 500A/40 VDC

87

 

76

 

 

 

44

 

 

38

 

32

 

 

 

 

@ 450A/38 VDC

75

 

65

 

 

 

38

 

 

32

 

28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

Duty Cycle

 

 

 

Amps

 

 

 

 

Volts at Rated Amperes

 

 

200 - 60% Duty Cycle

 

 

500

 

 

 

 

 

 

40 VDC

 

 

 

230/400/460 - 60% Duty Cycle

 

500

 

 

 

 

 

 

40 VDC

 

 

 

460/575 - 60% Duty Cycle

 

 

500

 

 

 

 

 

 

40 VDC

 

 

 

200 - 100% Duty Cycle

 

 

450

 

 

 

 

 

 

38 VDC

 

 

 

230/400/460 - 100% Duty Cycle

 

450

 

 

 

 

 

 

38 VDC

 

 

 

460/575 - 100% Duty Cycle

 

 

450

 

 

 

 

 

 

38 VDC

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

 

 

 

 

 

Constant Open

 

 

Continuous

 

 

 

Process

 

 

 

Circuit Voltage

 

 

Current Range

 

 

Current Ranges

 

 

 

75 Volts

 

 

5-540 Amps

 

 

GMAW 50-540 Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FCAW 40-540 Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STICK 30-540 Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pulse

 

 

Pulse

 

Pulse and Background

 

 

 

Pulse

 

 

 

Current Range

Voltage Range

 

 

Time Range

 

 

 

Frequency

 

 

 

 

 

 

 

 

 

 

 

5-750 Amps

5-55 Volts

 

100 Microsec - 3.3 Sec

 

 

0.15 - 1000 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECOMMENDED INPUT WIRE AND FUSE SIZES

 

 

 

 

 

 

 

 

 

 

Type 75°C

 

Type 75°C

 

Type 75°C

 

 

Input

 

Duty

Input Ampere Copper Wire in

Ground Wire in

 

(Super Lag)

 

 

Voltage/

 

Cycle

 

Rating on

 

Conduit

 

Conduit

 

or Breaker

 

 

Freqency

 

 

Nameplate

 

AWG[IEC]

 

AWG[IEC]

 

Size (Amps)

 

 

 

 

 

 

 

 

Sizes (MM2)

 

Sizes (MM2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200/50-60

 

60%

87

4

(25)

 

 

 

8

(10)

 

 

 

 

120

 

230/50-60

 

60%

76

4

(25)

 

 

 

8

(10)

 

 

 

 

100

 

400/50-60

 

60%

44

8

(10)

 

 

 

10

(6)

 

 

 

 

50

 

460/50-60

 

60%

38

8

(10)

 

 

 

10

(6)

 

 

 

 

50

 

575/50-60

 

60%

32

8

(10)

 

 

 

10

(6)

 

 

 

 

50

 

200/50-60

 

100%

75

4 (25)

 

 

 

8

(10)

 

 

 

 

100

 

230/50-60

 

100%

65

4

(25)

 

 

 

8

(10)

 

 

 

 

100

 

400/50-60

 

100%

38

8

(10)

 

 

 

10

(6)

 

 

 

 

50

 

460/50-60

 

100%

32

8

(10)

 

 

 

10

(6)

 

 

 

 

50

 

575/50-60

 

100%

28

8

(10)

 

 

 

10

(6)

 

 

 

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

 

 

 

 

 

 

 

 

 

Height

 

 

Width

 

 

Depth

 

 

 

Weight

 

 

 

905 mm

 

 

515 mm

 

 

1010 mm

 

 

 

138 kg

 

 

 

35.6 in.

 

 

20.3 in.

 

 

39.8 in.

 

 

 

304 lbs.

 

 

OPERATING TEMPERATURE RANGE STORAGE TEMPERATURE RANGE

0° to 40°C

-50° to 85°C

POWER WAVE 450

Page 9
Image 9