Lincoln Electric IM524-D manual Observe Safety Guidelines

Models: IM524-D

1 54
Download 54 pages 51.66 Kb
Page 46
Image 46

E-4

TROUBLESHOOTING

E-4

 

 

 

 

 

TROUBLESHOOTING GUIDE

 

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

Machine has no output – fans run

1. Make sure that the machine

 

 

 

– display is on.

was powered up with a properly

 

 

 

 

installed overlay. (With no overlay

 

 

 

 

on the machine or an invalid over-

 

 

 

 

lay, the machine will have no out-

 

 

 

 

put.)

 

 

 

 

2. Check to see if the Limits or

 

 

 

 

Setup overlay is installed on the

 

 

 

 

front panel. These two overlays

 

 

 

 

can not be used for welding.

 

 

 

 

3. Check for proper input voltage

 

 

 

 

(per machine nameplate).

 

 

 

 

4. Make certain the reconnect

 

 

 

 

panel is configured properly.

 

 

 

 

5. Check that when the trigger is

 

 

 

 

pulled on the wire feeder, the wire

 

 

 

 

feeder’s voltage display changes

If all recommended possible areas

 

 

to indicate arc voltage. If this does

of misadjustments have been

 

 

not happen, feeder may be faulty.

checked and the problem per-

 

 

6. Check feeder control cable for

sists, contact your local Lincoln

 

 

Authorized Field Service Facility.

 

 

loose or faulty connections.

 

 

 

 

 

 

7. If the machine is connected for

 

 

 

 

380 VAC or higher and has not

 

 

 

 

been used for a long period of

 

 

 

 

time, the capacitors may require

 

 

 

 

“conditioning.” Let the machine

 

 

 

 

run at an idle state (no load) for 30

 

 

 

 

minutes.

 

 

 

Machine regularly overheats – yel-

1. Welding application may

 

 

 

low light (LED) on the front panel

 

 

 

exceed recommended duty cycle.

 

 

 

glows, indicating a thermal over-

 

 

 

 

 

 

 

load. The fans run and the display

2. Dirt and dust may have clogged

 

 

 

is on.

the cooling channels inside the

 

 

 

 

machine. Refer to the

 

 

 

 

Maintenance Section of this man-

 

 

 

 

ual.

 

 

 

 

3. Air intake and exhaust louvers

 

 

 

 

may be blocked due to inade-

 

 

 

 

quate clearance around machine.

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact your local authorized Lincoln Electric Field Service Facility for technical assistance.

POWER WAVE 450

Page 46
Image 46
Lincoln Electric IM524-D manual Observe Safety Guidelines