Lincoln Electric IM666-A manual Installation, Technical Specifications Tandem MIG Torch

Models: IM666-A

1 25
Download 25 pages 37.62 Kb
Page 8
Image 8

A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS - Tandem MIG Torch

Tandem MIG Torch Cable Length Availability

Product Number

Gun Cable Length

 

 

 

G3494-2, 2A

4 ft

(1.2 m)

G3494-3, 3A

6 ft

(1.8 m)

G3494-4, 4A

8 ft

(2.4 m)

G3494-5, 5A

10 ft

(3.0 m)

G3494-6, 6A

12 ft

(3.6m)

 

 

 

Shielding Gas Flow Rate

65 scfh (31 liters/min) minimum

Water Cooling Flow Rate for each Power Cable

.45 gal/min at 40 psi

(1700 ml/min at 2.7 bar)

Water cooling flow rate for nozzle/gas cable

.45 gal/min at 40 psi

(1700 ml/min at 2.7 bar)

Lead Electrode size

0.035" to 5/64" (0.9 mm to 1.9 mm)

Trail Electrode size

0.035" to 5/64" (0.9 mm to 1.9 mm)

Duty Cycle

100% at 450 amps per side / 900 amps Total

Maximum current draw per electrode 650 amp / 60% duty cycle

PHYSICAL DIMENSIONS

HEIGHT

WIDTH

DEPTH

WEIGHT

17.54 in.

3.75 in.

4.5 in. (w/o bracket)

14.0 lbs (w/ 4 ft. cable)

445.5 mm

95.3 mm

114.3 mm (w/o bracket)

6.4 kg. (w/ 4 ft. cable)

 

 

 

 