A-4

INSTALLATION

A-4

 

 

 

 

SAFETY PRECAUTION

 

 

ELECTRIC SHOCK can

 

 

kill.

 

 

• Only qualified personnel should

 

 

perform this installation.

 

 

• Turn off the input power to the power source at

 

 

the disconnect switch or fuse box before work-

 

 

ing on this equipment. Turn off the input power

 

 

to any other equipment connected to the weld-

 

 

ing system at the disconnect switch or fuse

 

 

box before working on this equipment.

 

 

• Do not touch electrically hot parts.

 

 

----------------------------------------------------------------------

 

 

WELD CABLE SIZES

 

Table A.1 has the copper cable sizes recommended for different currents and duty cycles. Lengths stipu- lated are the distance from the welder to work and back to the welder again. Cable sizes are increased for greater lengths primarily for the purpose of mini- mizing voltage in the welding circuit.

TABLE A.1

RECOMMENDED CABLE SIZES (RUBBER COVERED COPPER - RATED 75°C)**

CABLE SIZES FOR COMBINED LENGTHS OF ELECTRODE AND WORK CABLES

 

 

Percent

 

0 to 50 Ft.

 

 

50 to 100Ft.

 

 

100 to 150 Ft.

 

 

150 to 200 Ft.

 

 

200 to 250 Ft.

 

 

 

Duty

 

 

 

 

 

 

31 to 48 m

 

 

48 to 61 m

 

 

61 to 76 m

 

 

Amperes

Cycle

0 to 15 m

 

 

15 to 31 m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200

60

 

2

 

 

2

 

 

2

 

 

1

 

 

1/0

 

200

100

 

2

 

 

2

 

 

2

 

 

1

 

 

1/0

 

225

20

 

4 or 5

 

 

3

 

 

2

 

 

1

 

 

1/0

 

225

40 & 30

 

3

 

 

3

 

 

2

 

 

1

 

 

1/0

 

250

30

 

3

 

 

3

 

 

2

 

 

1

 

 

1/0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

250

40

 

2

 

 

2

 

 

1

 

 

1

 

 

1/0

 

250

60

 

1

 

 

1

 

 

1

 

 

1

 

 

1/0

 

250

100

 

1

 

 

1

 

 

1

 

 

1

 

 

1/0

 

300

60

 

1

 

 

1

 

 

1

 

 

1/0

 

 

2/0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

325

100

 

2/0

 

 

2/0

 

 

2/0

 

 

2/0

 

 

3/0

 

350

60

 

1/0

 

 

1/0

 

 

2/0

 

 

2/0

 

 

3/0

 

400

60

 

2/0

 

 

2/0

 

 

2/0

 

 

3/0

 

 

4/0

 

400

100

 

3/0

 

 

3/0

 

 

3/0

 

 

3/0

 

 

4/0

 

500

60

 

2/0

 

 

2/0

 

 

3/0

 

 

3/0

 

 

4/0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

**Tabled values are for operation at ambient temperatures of 40°C and below. Applications above 40°C may require cables larger than recommended, or cables rated higher than 75°C.