B-9

OPERATION

B-9

S E T T I N G A R C S E N S I N G W I R E F E E D S P E E D FOR CONSTANT CURRENT OPERATION

When using a constant current (formerly variable voltage) power source, welding performance is improved using arc sensing wire feed speed (CC operation). In this wire feed mode the wire speed increases if arc voltage increases, and decreases if arc voltage decreases, but remains con- stant at any specific voltage level.

The LN-15 permits accurate presetting of the desired wire feed speed, for the desired arc voltage to be used, by setting the Wire Feed Speed in the following manner before welding:

a.Activate press and spin during power up and change to the CC mode. See “Changing the CV/CC mode or WFS units” in this Operation Section.

FIGURE B.4 CC WIRE SPEED SETTING

b. Referring to the graph located above the Mode switch (also shown in Figure B.4):

1.Select the horizontal line representing the DE- SIRED IN/MIN. for the welding procedure. (See example arrow line for 375 in/min.)

2.Select the diagonal line representing the ARC VOLTS to be used for the welding procedure. (See example arrow line for 29 volts.)

3.Determine the vertical line representing the CC WIRE SPEED SETTING where the above two lines cross. (See example arrow line for 450.)

c.Adjust the WFS display to the value determined in Step (3) above (450 for example used).

The wire will feed at the DESIRED IN/MIN speed when the welding power source is set to the arc voltage to be used for the weld procedure (375 in/min. at 29V for example used).

The CC wire speed setting graph is shown in TABLE B.1, giving the Wire Speed dial setting required for the DESIRED IN/MIN and ARC VOLTS used for the welding procedures:

TABLE B.1 CC WIRE SPEED SETTING

 

 

 

 

Arc Volts Used

 

 

 

 

Desired

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In/Min

16

18

20

22

24

26

28

30

32

34

 

 

 

 

 

 

 

 

 

 

 

50

109

97

88

80

73

67

63

58

55

51

60

131

117

105

95

88

81

75

70

66

62

70

153

136

123

111

102

94

88

82

77

72

80

175

156

140

127

117

108

100

93

88

82

90

197

175

158

143

131

121

113

105

98

93

100219 194 175 159 146 135 125 117 109 103

110241 214 193 175 160 148 138 128 120 113

120263 233 210 191 175 162 150 140 131 124

130284 253 228 207 190 175 163 152 142 134

140306 272 245 223 204 188 175 163 153 144

150328 292 263 239 219 202 188 175 164 154

160350 311 280 255 233 215 200 187 175 165

170372 331 298 270 248 229 213 198 186 175

180394 350 315 286 263 242 225 210 197 185

190416 369 333 302 277 256 238 222 208 196

200438 389 350 318 292 269 250 233 219 206

210459 408 368 334 306 283 263 245 230 216

220481 428 385 350 321 296 275 257 241 226

230503 447 403 366 335 310 288 268 252 237

240525 467 420 382 350 323 300 280 263 247

250547 486 438 398 365 337 313 292 273 257

260569 506 455 414 379 350 325 303 284 268

270591 525 473 430 394 365 338 315 295 278

280613 544 490 445 408 377 350 327 306 288

290634 564 508 461 423 390 363 338 317 299

300656 583 525 477 438 404 375 350 328 309

310678 603 543 493 452 417 388 362 339 319

320700 622 560 509 467 431 400 373 350 329

330642 578 525 481 444 413 385 361 340

340661 595 541 496 458 425 397 372 350

350681 613 557 510 471 438 408 383 360

360700 630 572 526 484 450 420 394 370

380

666

604

554

512

472

444

416

392

400

700

636

584

538

500

466

438

412

420

 

668

612

566

526

490

460

432

 

 

 

 

 

 

 

 

 

440

 

700

642

592

550

514

482

452

460

 

 

670

620

576

536

504

472

480

 

 

700

646

600

560

526

494

500

 

 

 

674

626

584

546

514

 

 

 

 

 

 

 

 

 

520

 

 

 

700

650

606

568

536

540

 

 

 

 

676

630

590

556

560

 

 

 

 

700

654

612

576

580

 

 

 

 

 

676

634

598

600

 

 

 

 

 

700

656

618

 

 

 

 

 

 

 

 

 

620

 

 

 

 

 

 

678

638

640

 

 

 

 

 

 

700

658

660

 

 

 

 

 

 

 

680

680

 

 

 

 

 

 

 

700

700

 

 

 

 

 

 

 

 

CCSpeed Setting = Desired IPM X 35 Arc Volts

LN-15 CONTROL CABLE MODEL (CE)

Page 23
Image 23
Lincoln Electric IM910 manual Figure B.4 CC Wire Speed Setting