| TROUBLESHOOTING | ||||
|
|
| Observe all Safety Guidelines detailed throughout this manual |
|
| |
|
|
|
|
|
| |
| ERRORS ON THE DISPLAY |
|
|
| ||
|
|
|
|
|
| |
| Fault Code | Description | Possible Adjustments |
|
| |
| Err 0081 | Average motor over current shutdown | • The wire drive motor has overheated. |
| ||
|
|
|
| • Check to make sure the electrode |
|
|
|
|
|
| slides easily through the liner of the |
| |
|
|
|
| gun. |
|
|
|
|
|
| • Reduce the amount of tension in the |
| |
|
|
|
| wire drive tension arm. |
|
|
|
|
|
| • Verify that the spindle brake is not set |
| |
|
|
|
| too tight. |
|
|
|
|
|
| • For best results, use only Lincoln elec- |
| |
|
|
|
| trodes. |
|
|
|
|
|
| • Wait 10 minutes for the wire feeder to |
| |
|
|
|
| cool. |
|
|
|
|
|
|
| ||
| Err 0086 | Trigger lockout. | • The ripple of the power source OCV is |
| ||
|
|
|
| too high, greater than 110V. (Across |
| |
|
|
|
| the Arc Models only) |
|
|
|
|
|
| • Verify the power source is reconnect- |
| |
|
|
|
| ed for the proper input voltage. |
|
|
|
|
|
| • Repair or replace the power source. |
| |
|
|
|
| The power source does not conform to |
| |
|
|
|
| NEMA |
|
|
|
|
|
|
|
|
|
CAUTION