Lincoln Electric IM910 manual Across the ARC Model, Figure B.1a

Models: IM910

1 36
Download 36 pages 63.77 Kb
Page 17
Image 17

B-3

OPERATION

B-3

CASE FRONT CONTROLS (See Figure B.1)

ACROSS THE ARC MODEL

1.WIRE FEED SPEED DISPLAY-The Wire Feed Speed display shows the rate the LN-15 will feed electrode dur- ing welding. The default WFS units for domestic models are inches/minute and can be changed to meters/minute through the configuration menu. The default WFS units for the European models are m/min. The wire feed speed is calibrated to within ±2%.

2.VOLTAGE DISPLAY-The voltage display shows the average arc voltage during the welding. A minus sign "-" appears when welding with electrode negative welding procedures. While welding, an LED will illuminate below the voltage display. After welding, the average voltage will continue to be shown for 5 seconds after the end and the LED will flash. of the weld. When not welding, the display shows "- - - ". The voltage is calibrated to ±2% over a range of 10 to 45 volts.

The voltage display is not a "preset" voltage. Refer to the examples from Figure B.1a.

3.WIRE FEED SPEED KNOB-The Wire Feed Speed knob is a 3-3/4 turn potentiometer that adjusts of the rate of feeding electrode. The wire feed speed range is 50 -

700inches/min (1.3 - 17.8 m/min)

FIGURE B.1a

4.VOLTAGE KNOB-The voltage knob is present only on control cable models.

Adjusting the voltage knob varies the power source volt- age to the LN-15. The value displayed is not a "preset" voltage. Only actual average arc voltage is shown on the voltage display.

For codes 10864, 10865:

The voltage knob controls the output of the power source through a 3-3/4 turn, 10K ohm potentiometer.

For codes 11033 and above:

The voltage knob controls the output of the power source through a _ turn, 10K ohm potentiometer.

5.TRIGGER CONNECTOR-5 Pin Receptacle is used to activate the Magnum Gun Switch.

6.CONNECTOR BUSHING-This connection is for weld- ing conductor cable assembly.

7.ON / OFF SWITCH-For codes 11033 and above:

The ON / OFF Switch turns power on and off to the wire feeder.

83% PROCEDURE

The LN-15 supports a special "dual procedure" mode. When activated, the wire feed speed is reduced to 83% of the set value, but no less than 50 inch- es/minute (1.27 m/min). The 83% procedure is most commonly used during pipe and out of position weld- ing. Requires Magnum 400 Dual Procedure Gun Equivalent.

FIGURE B.1

1 2

34

7

6

 

5

 

LN-15 CONTROL CABLE MODEL (CE)

Page 17
Image 17
Lincoln Electric IM910 manual Across the ARC Model, Figure B.1a