INSTALLATION | ||
|
|
|
TECHNICAL SPECIFICATIONS - POWER WAVE 455M/STT (CE) (K2203-4)
INPUT AT RATED OUTPUT - THREE PHASE ONLY
INPUT | OUTPUT CONDITIONS | INPUT |
VOLTS | AMPS / VOLTS / DUTY CYCLE | CURRENT |
| EXCEPT STT PROCESS | AMPS |
|
|
|
380V - 60Hz. | 400A@36V. 100% | 36 A |
380V - 50Hz. | 400A@36V. 100% | 36 A |
415V - 60Hz. | 400A@36V. 100% | 33 A |
415V - 50Hz. | 400A@36V. 100% | 33 A |
|
STT PROCESS ALL VOLTAGES
325A@33V. 100%
OUTPUT CONDITIONS | INPUT |
AMPS / VOLTS / DUTY CYCLE | CURRENT |
EXCEPT STT PROCESS | AMPS |
|
|
500A@40V. 60% | 48 A |
500A@40V. 60% | 48 A |
500A@40V. 60% | 44 A |
500A@40V. 60% | 44 A |
STT PROCESS ALL VOLTAGES |
|
325A@33V. 100% |
|
|
|
OUTPUT
OPEN | CURRENT | PULSE | PULSE | PULSE AND | STT PARAMETERS | AUXILIARY |
CIRCUIT | RANGE | FREQUENCY | VOLTAGE | BACKGROUND | PEAK & BACK- | POWER |
VOLTAGE | AMPS |
| RANGE | TIME RANGE | GROUND CURRENT |
|
|
|
|
|
|
|
|
75 VDC | 5 - 570 A | 0.15 - 1000 Hz | 5 - 55 VDC | 100 MICRO SEC. | 40 VDC AT | |
|
|
|
| - |
| 10 AMPS |
|
|
|
| 3.3 SEC. |
|
|
|
|
|
|
|
| 220 VAC AT |
|
|
|
|
|
| 5 AMPS |
|
|
|
|
|
|
|
PROCESS CURRENT RANGE (DC)
MIG/MAG
FCAW
SMAW
Pulse
STT
CURRENT AMPS
RECOMMENDED INPUT WIRE AND FUSE SIZES
INPUT | DUTY | INPUT AMPERE | TYPE 75°C | TYPE 75°C | TYPE 75°C | |
COPPER WIRE | GROUND WIRE | (SUPER LAG) | ||||
VOLTAGE / | CYCLE | RATING ON | ||||
IN CONDUIT | IN CONDUIT | OR BREAKER | ||||
FREQUENCY |
| NAMEPLATE | ||||
| AWG[IEC] SIZES | AWG[IEC] SIZES | SIZE (AMPS) | |||
|
|
| ||||
|
|
| (mm2) | (mm2) |
| |
380V Hz. | 100% | 36 A | 8 (10) | 10 (6) | 40 A | |
415V Hz. | 100% | 33 A | 8 (10) | 10 (6) | 40 A | |
|
|
|
|
|
|
PHYSICAL DIMENSIONS
HEIGHT
663mm (26.10 in)
WIDTH
505mm (19.86 in)
DEPTH
835mm (32.88 in)
WEIGHT
121kg.
(267 lbs.)
TEMPERATURE RANGES
OPERATING TEMPERATURE RANGE
STORAGE TEMPERATURE RANGE