E-5
TROUBLESHOOTING
E-5
POWER WAVE 455M/STT (CE)
Observe all Safety Guidelines detailed throughout this manual
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con-
tact your local authorized Lincoln Electric Field Service Facility for technical assistance.
PROBLEMS
(SYMPTOMS) POSSIBLE AREAS OF
MISADJUSTMENT(S) RECOMMENDED
COURSE OF ACTION
OUTPUT PROBLEMS
Thermal LED is lit.
Machine wont weld, cant get any
output. (CR1 will not pull in.)
1. Fan thermostat has opened.
Check for proper fan operation.
(Fan should run whenever output
power is on.) Check for material
blocking intake or exhaust lou-
vers, or for excessive dirt clog-
ging cooling channels in
machine.
2. Secondary rectifier or Choke
thermostat has opened. After
machine has cooled, reduce
load, duty cycle, or both. Check
for material blocking intake or
exhaust louvers.
3. DC Bus PC board thermostat
has opened check for excessive
load on 40VDC supply.
1. Input voltage is too low or too
high. Make certain that input volt-
age is proper, according to the
Rating Plate located on the rear
of the machine.
2. If the Thermal LED is also lit, see
Yellow Thermal LED is Lit sec-
tion.
3. Primary current limit has been
exceeded. Possible short in out-
put circuit. Turn machine off.
Remove all loads from the output
of the machine. Turn back on. If
condition persists, turn power off,
and contact an authorized
Lincoln Electric Field Service
facility.
4
.This problem will normally be
accompanied by an error code.
Error codes are displayed as a
series of red and green flashes by
the status light. See
"Troubleshooting the Power Wave
/ Power Feed System Using the
Status LED" section of this text.
If all recommended possible areas
of misadjustments have been
checked and the problem persists,
contact your local Lincoln
Authorized Field Service Facility.