Lincoln Electric IM931 manual Installation, Technical Specifications Ranger 250 LPG K2336-2

Models: IM931

1 52
Download 52 pages 28.74 Kb
Page 9
Image 9

A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS - RANGER 250 LPG (K2336-2)

INPUT - LPG ENGINE

Make/Model

Description

Horsepower

Operating

Displacement cu. in.(cu. cm)

 

@ 3600 RPM

SPEED

Bore x Stroke in.(mm)

Starting System

Capacities

 

 

 

 

 

12VDC Battery

 

 

 

 

High

 

and starter

 

 

2 Cylinder

 

 

 

 

Kohler

 

3700RPM

 

Push Button

Fuel: LPG

4 Cycle

 

 

 

CH730S

Air Cooled

25 HP

Full Load

44 (725)

Starter

Cylinder

OHV

LPG

 

3500RPM

3.27x 2.64 (83x67)

 

Oil: 2.0Qts.(1.9L)

 

Engine

 

Low Idle

 

Group 58 Battery

 

 

 

 

 

(435 cold

 

 

 

 

2400RPM

 

 

 

 

 

 

 

crank amps)

 

 

 

 

 

 

 

 

RATED OUTPUT @ 104°F(40C°) - WELDER

Welding Output

Volts at Rated Amps

Duty Cycle Max.

OCV @ 3700 RPM

CC STICK & PIPE DC Output

28 Volts at 250 Amps

100%

 

STICK / PIPE Output Range

40 to 250 Amps

 

 

TIG Output Range

20 to 250 Amps

 

60 Volts

CV WIRE DC Output

28 Volts at 250 Amps

100%

 

CV WIRE DC Output

27 Volts at 275 Amps

60%

 

CV WIRE Output Range

14 to 28 volts

 

 

 

 

 

 

RATED OUTPUT @ 104°F(40C°) - GENERATOR

Auxiliary Power 1

10,500 Watts Peak, 9,500 Watts Continuous, 60 Hz

120/240 Volts

PHYSICAL DIMENSIONS

 

HEIGHT

WIDTH

 

DEPTH

 

 

WEIGHT

 

30.00** in.

21.50 in.

 

42.25 in.

 

 

 

 

762.0 mm

546.0 mm

 

1073.0 mm

 

482 lbs. (218kg.)

 

 

 

 

 

 

 

 

 

 

 

**Top of enclosure, add 6.0” (152mm) for exhaust.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENGINE COMPONENTS

 

 

 

 

LUBRICATION

 

VALVE LIFTERS

 

 

FUEL SYSTEM

 

GOVERNOR

 

Full Pressure

 

Hydraulic- (Kohler)

 

 

LPG regulator and

 

Mechanical Governor

 

with Full Flow Filter

 

 

 

 

vaporizer

 

5% Regulation (Kohler)

 

 

 

 

 

 

 

 

 

 

AIR CLEANER

 

ENGINE IDLER

 

 

MUFFLER

 

ENGINE PROTECTION

 

 

 

 

 

Low noise Muffler: Top outlet

Shutdown on low oil

 

Dual Element

 

Automatic Idler

 

can be rotated. Made from

pressure.

 

 

 

 

 

long life, aluminized steel.

 

 

 

 

 

 

 

 

 

 

 

 

1.Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.

RANGER 250 LPG

Page 9
Image 9
Lincoln Electric IM931 manual Installation, Technical Specifications Ranger 250 LPG K2336-2