SECTION 4 − INSTALLATION

 

 

 

 

4-1.

Specifications

 

 

 

 

 

 

Specification

Description

 

 

 

 

Overall Dimensions

Height: 10 in (254 mm); Width: 14-1/2 in (368 mm); Depth: 16 in (406 mm)

 

 

Weight

 

Net: IH/TS (no recorder) 13.1 lb (5.9 kg); IH/TS (digital recorder) 21.1 lb (9.6 kg)

 

 

Type Of Input Power

24 Volts DC, 115 Volts AC

 

 

 

 

Memory Capacity

One Program Up To 8 Segments

 

 

 

 

Control Capacity

Single Power Source Control

 

 

 

 

Operating Temperature Range

41° To 104° F (5° To 40° C)

 

 

 

 

Storage Temperature Range

−4° To 122° F (−20° To 50° C)

 

 

 

 

Reference the controller and recorder manuals for additional information.

 

 

 

 

4-2.

IH/TS Installation

 

 

 

 

 

 

 

Y Turn Off and

disconnect

 

 

 

 

input power.

 

 

 

 

 

5 kW System

 

 

 

 

1

1.

Temperature

 

 

 

 

 

Control/Recorder

 

 

1

 

2.

5kW Mounting Bracket

 

 

 

8

3.

Screw, 10-32 (4)

 

 

 

 

Install and secure IH/TS to mount-

 

 

 

 

 

 

ing bracket using supplied #10

4

 

8

screws.

 

 

 

 

4.

5kW Power Source Case

 

 

 

7

5. Case Sheet Metal Screw (4)

 

 

Remove case sheet metal screws

 

 

 

 

 

2

from both top left and right sides of

 

 

unit. Install mounting bracket to

 

 

6

 

 

power source and secure by rein-

 

 

 

 

 

5

stalling sheet metal screws.

 

 

 

25 kW System

 

 

 

 

 

 

 

 

 

 

6. 25 kW Power Source Case

 

 

 

7.

Rear Mounting Bracket

 

 

 

 

8.

Screw, 1/4-20 (2)

 

 

 

 

Remove front and middle mounting

 

 

3

screws from top of Item 6 case. Lo-

 

 

4

cate IH/TS and reinstall

front

 

 

 

mounting screws.

Locate

rear

 

 

 

mounting bracket, and secure with

 

 

 

supplied 1/4-20 screws. Reinstall

 

 

 

middle mounting screws to secure

 

 

 

bracket to case.

 

 

Tools Needed:

3/8, 5/16 in

Ref. 802 905-A / 802 900

OM-203 185 Page 8

Page 12
Image 12
Miller Electric manual Specifications, IH/TS Installation, Specification Description