Trouble

 

Remedy

 

 

2408 Temperature Controller reads

See Section 8-3I.

greater than 5° F different than

 

Channel 1 on 5100V Recorder.

 

 

 

 

 

2408

Temperature

Controller

Check and secure connections to the workpiece.

readings fluctuate

rather

than

 

remain stable.

 

 

 

 

 

 

 

5100V

Recorder screen

blinks

Screen calibration needs adjusting. Turn off IHTS power switch. Turn on IHTS power switch while touching

when touched, but does not

screen, and continue to touch screen (about 45 seconds) until configuration display appears on the screen.

advance to next screen.

 

Press “Touch Cal” or wait a few minutes for the Touch Cal display to appear on the screen. Use a pointed object

 

 

 

 

(be careful not to damage screen), and touch each set of cross hairs to calibrate screen. When calibration

 

 

 

 

is complete, turn IHTS power off and back on again.

 

 

5100V Recorder does not recognize

Floppy disks do not work well in ambient temperatures greater than 104° F (40° C).

floppy disk.

 

 

 

 

 

Clean floppy drive with a disk drive cleaner (available from a local computer reseller).

 

 

 

 

 

 

 

 

 