Miller Electric IH, TS manual Connecting 25kW System Cords And Cables, Front, Rear

Models: TS IH

1 76
Download 76 pages 57.26 Kb
Page 14
Image 14

4-5. Connecting 25kW System Cords And Cables

Hose From Cooler To

Power Source

Red

Hose

Yellow From Power

14-Pin

Control Cable

Output

Source To IH/TS

Connectors

Blue

Blue

Yellow

110 Volt From

IH/TS

Red

Front

Connect the power output cable and coolant lines as shown.

Connect 110-volt power cable as shown.

Plug the 110-volt cooler power cord into the duplex at the rear of the power source cart. On the 25kW system, the cooler must be plugged into the right side duplex. This is identified with a label that reads “switched receptacle.” The ON-OFF switch located to the left operates this

110 Volt From

Hose From

Cooler

IH/TS To

 

Cooler

plug.

The IH/TS Control is plugged in the left side duplex. Do not use these duplex connections for operating auxiliary tools, such as grinders, drills, lights, etc.

Connect output power cables to the output connectors.

.All coolant connections have 5/8-18 left-hand threads.

Rear

803 036-C

DConnect the “coolant out” line from the cooler directly to the output ex- tension cable.

DConnect the “coolant in” line on the IH/TS directly to the remaining output extension cable connection.

DConnect the “coolant out” line from the IH/TS to the “coolant in” line on the cooler.

OM-203 185 Page 10

Page 14
Image 14
Miller Electric IH, TS manual Connecting 25kW System Cords And Cables, Front, Rear