4-7. Connecting External Device

1

6

5

The IH/TS must have (as a minimum) one thermocouple connected to receptacle TC1. If multiple thermocouples are desired, either use individual thermocouple plugs or the thermocouple extension cable.

To connect thermocouples to the control, proceed as follows:

Turn Off power source.

1.Temperature Controller

2.Thermocouple Receptacles

3.Individual Thermocouple Plug

4.Thermocouple Extension Cable

Align plug pins with receptacle sockets and push plug into receptacle.

2

 

 

5. Coolant Line From Coil

 

 

 

6. Coolant Line To Cooler

 

 

 

“Coolant In” Port

 

 

 

The IH/TS is supplied with an

 

 

 

internal coolant flow switch.

 

 

4

Coolant hoses must be connected

 

 

to the IH/TS for proper operation.

 

 

 

 

 

 

Connect coolant hoses (supplied

 

3

 

with post-heat systems) to coolant

 

 

fittings on unit as described in

 

 

 

 

 

 

Section 4-5.

Tools Needed:

11/16 in

Ref. 803 003-B

OM-203 185 Page 12