Miller Electric TS, IH manual Example Stress Relief Profile, Step to 600 F, Ramp rate, Deg/ hr

Models: TS IH

1 76
Download 76 pages 57.26 Kb
Page 27
Image 27

Step to 600° F

as fast as possible*

Ramp to 1350° F

@ 600° /hr

Dwell @ 1350° F for 1/2 hour

Ramp to 600° F

@ 600° /hr

Free fall to ambient

SEG.n

1

tYPE StEP

(step)

tGt 600

(deg)

SEG.n

2

tYPE rmP.r

(ramp rate)

tGt 1350

(deg)

rAtE 600

(deg/ hr)

SEG.n

3

tYPE dwEl

(soak)

dur 0.5

(in hrs)

SEG.n

 

 

SEG.n

 

4

 

 

5

 

 

 

 

 

 

 

 

 

 

tYPE

 

 

tYPE

 

rmP.r

 

 

End

 

 

 

 

 

 

(ramp rate)

 

(end)

 

 

 

 

tGt

 

 

End.t

 

600

 

 

S OP

 

 

 

 

 

 

(deg)

(sets output to 0)

 

 

 

 

rAtE

 

 

 

 

600

 

 

 

 

 

 

 

 

 

(deg/hr)

 

 

 

Example Stress Relief Profile

 

1400

 

 

 

 

 

 

 

 

 

 

1200

 

 

 

 

 

 

 

 

 

 

1000

 

 

 

 

 

 

 

 

 

F

800

 

 

 

 

 

 

 

 

 

Degrees

 

 

 

 

 

 

 

 

 

600

 

 

 

 

 

 

 

 

 

400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

0

30

60

90

120

150

180

210

240

270

Time (minutes)

.*On small diameter pipe, it may be necessary to reduce the

output of the power source to achieve a “reasonable rate” in Segment 1; thereafter, the program controls the rate of temperature rise and the output power may be increased to full if desired. To reduce output power, turn power source output knob to desired setting.

Figure 6-2. Setting Stress Relief Profile Using Example Parameters