Ribbon cable may be disconnected inside of recorder after prior maintenance, reconnect ribbon cable. If above procedures do not clear the error message, replace recorder.

I.2408 Temperature Controller Reads Greater Than 55 F Different Than Channel 1 On 5100V Recorder Remove IH/TS wrapper.

Check that red (−) and yellow (+) leads are secure between clamp and copper pad on rear of temperature controller. Connect a thermocouple to TC1 input.

If temperature controller drifts while power source is off, replace temperature controller. If recorder readings drift while power source is off, replace recorder.

If power source output varies (audible frequency change) while attempting to maintain temperature, replace temperature controller.

If recorder readings drift while temperature controller is maintaining temperature, replace recorder.

8-4. Resetting All RAM Variables In The Event Of Display Errors

1

2

3

4

R e l e a s e B u t t o n

P r e s s

 

P o w e r S o u r c e

S e l e c t

T o R e s e t

R E S E T T I N G ME MO RY

ME MO R Y RE S E T

.This procedure will reset all

stored variables in RAM memory including scaling, programs, counters, and security code.

Before turning on power at the power source, press and hold Power Source Select button.

Turn on power at power source.

1 Release Button Display

When “Release Button” appears on the display, release the button.

2Press Power Source Select To Reset Display

After the display changes to “Press Power Source Select To Reset”, press Power Source Select button to reset all stored variables in RAM.

3RESETTING MEMORY Display

“RESETTING MEMORY” will appear on the display automatically during the RAM memory reset operation.

4 “MEMORY RESET” Display

“MEMORY RESET” will appear on the display after completion of RAM memory reset.

The IH/TS will restart with factory set default parameters in RAM memory.