Single File With No Batch Name

Data is continuously stored in the recorder.

If a batch was not started, the temperature data is still recorded. The Job# (Batch Name), User, Comments and Recorder ID are not recorded.

The file name would consist of: Group_DescriptorTime/Date_stamp.uhh (no Batch Name).

The file creation time can be found using the Detail Button.

Select the desired file. Select “Open”.

scrn6

Enter the Job# (Batch Name) in the field next to “Select or Enter Instrument tag:

This is the “File name” the information will be stored in.

If a batch was not started, enter the Job# (Batch Name) in the field next to “Enter Batch Name if Required:” as well.

Select “Start Transfer”.

Proceed to “New Instrumentpop-up window (top of page 37).

scrn7

OM-203 185 Page 36

Page 40
Image 40
Miller Electric IH, TS manual Single File With No Batch Name, Select Start Transfer