1.Energize IH/TS and power source. A coolant flow error should appear on the IH/TS display. Energize the cooler and the error will clear from the display.

2.Set up Temperature Profile − per code requirements (see Section 6-3-2Programming The 2408 Controller).

3.Set up and start Digital Recorder

Digital Recorder (see Section 6-3-3. Batch Recording On The 5100 Digital Recorder)

4.Run the heat process (see Section 6-3-4. Running A Heat Treat and the following tables).

5.Recover from an interruption, if applicable (see Section 6-3-5. Recovering From An Interruption).

6.Retrieve data

Digital Recorder (see Section 6-3-3-4. Batch Recording On The 5100 Digital Recorder) View and print data (see Section 6-3-6Review Software).

Name

Home

OP

Table 6-1. Controller Display Definitions

Description

Home List (extra parameters may be present.)

Measured value and Setpoint

% Output level

Table 6-2. Run List Sub-Menu Definitions

run

program run List

 

 

StAt

Program status (OFF, run, hoLd, HbAc, End)

 

 

PSP

Programmer setpoint

 

 

SEG

Active segment number

 

 

StyP

Active segment type

 

 

SEG.t

Segment time remaining in the segment units

 

 

tGt

Target setpoint

 

 

rAtE

Ramp rate (if a rate segment)

 

 

PrG.t

Program time remaining in hours

 

 

SEG.d

*Flash active segment type in the lower readout of the home display (no/YES)

 

 

FASt

Runs through program 10 times faster than normal

 

 

*This parameter can only be changed when the program is in reset.